Plumbing Connections

Figure 2. Typical Installation Diagram

PLUMBING CONNECTIONS 

The flow control valve, syphon breaker and solenoid 
valve are supplied with all complete disposer packages 
(packed separately).

Make certain that the solenoid valve supplied is  
the proper voltage. Make certain that the valves are 
plumbed according to water flow direction arrows 
marked on valves or the valves will not  
function properly.

The flow control valve regulates all water flowing into 
the disposer. This conserves water and prevents  
overloading. Check direction of water flow arrows.

Syphon breaker must be installed above the sink flood 
plane 

per local plumbing codes

. Check direction of 

water flow arrows.

Summary of Contents for 15257

Page 1: ...this appliance carefully reads and understands the Safety Instructions contained in this manual NOTICE is used to address practices not related to physical injury CAUTION indicates a hazardous situati...

Page 2: ......

Page 3: ...60V 3 phase 1 2 10 HP 11 Warranty FOODSERVICE DISPOSER CONTROL CENTER LIMITED WARRANTY InSinkErator Foodservice Disposer Control Centers are warranted against defects in material and workmanship for o...

Page 4: ...oser motor will reverse its direction of rotation automatically upon restart To avoid motor damage a five second delay feature prevents reversing while motor is coasting ENCLOSURE Stainless steel NEMA...

Page 5: ...upplied is the proper voltage Make certain that the valves are plumbed according to water flow direction arrows marked on valves or the valves will not function properly The flow control valve regulat...

Page 6: ...minutes and factory set to provide approximately a 5 minute delay To adjust SHUT OFF ELECTRIC POWER Inside unit locate the adjustment potentiometer Turn clockwise to increase delay Turn counterclockw...

Page 7: ...HOOTING This control center was inspected and tested under operating conditions before shipment from the factory In case of trouble check the items listed below A Disposer motor will not start and wat...

Page 8: ...alled at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the control center voltage and phase match the disposer motor and electrical supply Check nameplates on dispose...

Page 9: ...talled at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the control center voltage and phase match the disposer motor and electrical supply Check nameplates on dispos...

Page 10: ...stalled at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the control center voltage and phase match the disposer motor and electrical supply Check nameplates on dispo...

Page 11: ...stalled at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the control center voltage and phase match the disposer motor and electrical supply Check nameplates on dispo...

Page 12: ......

Reviews: