16
NS-UZ14XSS8
www.insigniaproducts.com
How do I reset my freezer to factory
defaults?
1
Press and hold
Lock
for three seconds to unlock the control panel.
2
Press the
Lock
and
+
buttons at the same time for three seconds to
reset the freezer to factory defaults. The panel beeps and all of the
indicators turn on for three seconds. If the compressor is running, it
pauses for five minutes, then restarts.
Troubleshooting
Fault indication
If a fault is detected, the display shows one of the following codes. If a
fault is indicated, call for service:
General
Caution
Do not try to repair your freezer yourself. Doing so invalidates the
warranty.
Fault code
E2
E5
E7
Description
Temperature sensor fault
Defrost sensor fault
Ambient Temperature sensor fault
PROBLEM
POSSIBLE CAUSE
POSSIBLE SOLUTION
E2 appears on the
display
Temperature sensor failure.
Call for service.
E5 appears on the
display
Defrost sensor failure.
Call for service.
E7 appears on the
display
Ambient temperature sensor
failure.
Call for service.
High Temp and Door
Open alerts
See “Understanding Alerts” on page 15.
The freezer does not
operate
The freezer is unplugged.
Make sure that the freezer is plugged in and that the plug is
pushed completely into the outlet.
The fuse on the circuit is blown
or the circuit breaker is tripped.
Check the house fuse/circuit breaker box and replace the fuse or
reset the circuit breaker.
Power failure.
If a power failure occurs, the freezer turns off. Wait until the
power is restored.