INSTALLATION INSTRUCTIONS
Gas ignition: Your dryer uses an automatic ignition system to ignite the burner.
There is no constant burning pilot.
COMMONWEALTH OF MASSACHUSETTS INSTALLATION
INSTRUCTIONS
Your dryer must be installed by a licensed plumber or gas fitter. A “T” handle
manual gas valve must be installed in the gas supply line to the installed dryer at
the location of operation.
If a flexible gas connector is used to connect the dryer, the connector may not be
longer than 3 ft. (91.5 cm).
Grounding requirements
Your dryer must be grounded. If a malfunction or breakdown occurs, the
grounding reduces the risk of electrical shock by providing a path of least
resistance for the electrical current.
Gas models
Electric models
WARNING:
Gas leaks may occur in your system, creating a dangerous situation.
• Gas leaks may not be detected by smell alone.
• Gas suppliers recommend that you purchase and install a UL-approved gas
detector.
• Install and use it in accordance with the manufacturer’s instructions.
WARNING:
• Your dryer has a three-prong power cord with grounding conductor (120 V,
60 Hz).
• The plug must be plugged into an appropriate outlet that is properly installed
and grounded in accordance with all local codes and ordinances.
• Certain internal parts are intentionally not grounded and may present a risk
of electric shock only during servicing. Service Personnel – Do not contact the
following parts while the appliance is energized: inlet valve, control board,
and temperature-regulating thermistor (located on blower housing).
WARNING:
• Dryer must be grounded with three- or four-wire cord power cord with a
grounding conductor and a grounding plug, which is sold separately.
• The plug must be plugged into an appropriate outlet that is properly installed
and grounded in accordance with all local codes and ordinances.
• Do not modify the plug provided with your dryer - if it doesn’t fit the outlet,
have a proper outlet installed by a qualified electrician.
• If a power cord is not used and the electric dryer is to be permanently wired,
the dryer must be connected to a permanently grounded metal wiring
system, or an equipment grounding conductor must be run with the circuit
conductors and connected to the equipment grounding terminal or lead on
the dryer.
• Certain internal parts are intentionally not grounded and may present a risk
of electric shock only during servicing. Service Personnel – Do not contact the
following parts while the appliance is energized: inlet valve, control board
and temperature-regulating thermistor (located on blower housing).