www.insigniashowers.com
Last Modified: 08/12/2021
16
Step 8 —
Control panel and electrical connections
Connect all wires, matching the
image labels to ensure correct
connection.
All connections
MUST
be carried out by an approved part P electrician and a
minor works certificate must be issued upon completion. This product is NOT
designed for DIY install and improper installation could be fatal.
Please use correct size and type to meet electrical codes. Leave 2 feet of slack
wire at generator location for finish hook
-
up. Connect the generator to a
dedicated circuit breaker.
ELECTRICAL FINISH
A.
Route the supply wire through the hole marked POWER.
B.
Connect the supply wires to terminals marked L1, L2 & L3 and N. Please
see Diagram for 240v Conversion
C.
Connect the ground to the ground screw marked accordingly.
Single Phase 220/240v
Connect 3 x live wires in to (L1) then
(L2) and (L3). Connect the 1 neutral
Cable in to position (N) & finally 1 x
Earth Cable to the earth screw on the
plate.
Connect 1 x live wire in to (L1) then
bridge (L1+L2) and (L2 + L3) as show in
the picture above. Connect the 1 neu-
tral Cable in to position (N) & finally 1 x
Earth Cable to the earth screw on the
plate.
3 Phase 380v