Pressure Requirements from your house supply

 

We recommend a bar pressure between 2 and 3.4 BAR. If you have a combi boiler system no problem should be experienced. If you have a gravity feed older type          

installation (hot water tank type usually less than 1 bar) you will almost certainly need a pump. We cannot advise on which type of pump is used, location or design because 

all house plumbing layouts vary. This is a job for your installer/plumber. The end delivery however must fall within the scope above. 

 

 

 

Debit Requirements 

You will need the debit capabilities of at least 10 litres per minute. Again an average combi boiler will supply this but please check if you have a gravity feed system.   

Important Note

 Do not exceed 3.4 BAR pressure under any circumstances. Warranty is void if so as damage will occur.  If you have a combi supply, please use a pressure 

reducing valve if required to lower the BAR pressure to the shower. 

Please Remember that this product is free standing and is designed to be pulled away from the wall. The water supply and waste require flexible pipes. If you purchased the 

fitting kit with this shower you will have the required fittings. The water supply pipes need to be at least 1 metre in length and  must be that of a flexi braided type. 

 

 

Please note if a shower pump is used via gravity system we recommend a separate cold feed bypassing pump direct to generator to avoid damage to the       

generator

.  

 

Further to this as you would with a washing machine or dishwasher, it is highly recommended that accessible water valve taps are installed to turn off the shower when not  

In use. This will avoid any possible flooding due to a burst pipe or connection failure in the future. 

 

All manuals and user guides at all-guides.com

Summary of Contents for GT8728

Page 1: ...r postcode to hand before calling Email customerservice insigniarange co uk Replacements Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts ou...

Page 2: ...What s In The Boxes Screw Pack Contents Plumbing Requirements Starting The Installation Electric Box Connections Steam Generator Connections Sealing and Water Testing MK117 Control Panel Instructions...

Page 3: ...erything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your finish OUR BADGE RATING I...

Page 4: ...MAINS WHEN YOUR ITEM IS ASSEMBLED ALWAYS USE THE SERVICES OF A FULLY QUALIFIED ELECTRICAL COMPANY TO COMPLETE CONNECTION FROM SHOWER TO HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WAR...

Page 5: ...hin current laws and IP directives using plug and RCD provided with steam version or supply one for non steam version 2 Preferred Wire into isolated fused feed connecting directly to the house consume...

Page 6: ...word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit apart and carry out the...

Page 7: ...arts can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Product Code Descrip on Quan ty SP09...

Page 8: ...ny circumstances Warranty is void if so as damage will occur If you have a combi supply please use a pressure reducing valve if required to lower the BAR pressure to the shower Please Remember that th...

Page 9: ...ost cases this is blanked yet should you have a steam version you need to gently drill this out as this item is for the steam generator drainage and will be connected in the instructions later Now ple...

Page 10: ...tep is to attach both front fixed glass panels In order to do this take the glass panel the large black edge to be situated on the entrance side to the shower and offer it up to the upright as shown b...

Page 11: ...as shown by the arrows in the image Next screw the inner uprights to your curved rails using the ST10 screws please note that the front uprights will need a pilot hole drilled before screwing Step 5...

Page 12: ...f the glass doors and ensure the wheels are at their lowest position and hang on the inner curved rails with the wheels facing the outside of the glass Once all wheels are fitted and on the rails you...

Page 13: ...he provided white plastic foot massage retaining knobs to your glass back panel along with your chrome water outlet as shown in the above image To hang the foot massager itself to the wall push the ma...

Page 14: ...f the probe Ozone o3 Unscrew the chrome pepper pot end and drop the white box upside down into the rear hole as shown in the image Now from the inside of the shower re attach the chrome pepper pot end...

Page 15: ...o your outer chrome faceplate in side your Insignia shower as a reference point IF YOUR DIAL DOES NOT CORROSPOND TO THE APPROPRIATE DEVICE Turn on your water to the shower and note which output the wa...

Page 16: ...Connections Phono AUX CD MP3 Thermostatic Probe RJ11 Phone Connection Radio Aerial Fan Speaker Ozone o3 Light Light 2 Earth Connect the cables below to the corresponding devices on the shower All manu...

Page 17: ...will result in crazing of acrylic due to excessive heat generated on it Always be aware of the steam outlet pod position Never use in close proximity to the person using it Never use this shower if y...

Page 18: ...are fitted in the correct position as they are only attached for transportation reasons only Water Inlet Connect a braided hose from the shower valve s centre feed to this opening Drain Connect the gr...

Page 19: ...then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area thoroughly and reseal on the OUTSIDE Please r...

Page 20: ...tween manual auto radio searching Button 9 Up Arrow Channel select up manual search up Button 10 Alarm Activate Alarm Button 11 M Set Steam Time Temperature When Radio is active this button will activ...

Page 21: ...25 07 2013 21 Need Help If so then simply download Insignia s free comprehensive help and troubleshooting brochure now Simply visit www insigniarange co uk help aspx All manuals and user guides at all...

Page 22: ...r form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All images are registered w...

Reviews: