Silicone Seal where shown in red on the inside of the shower

 

TESTING FOR WATER LEAKS

 

LEAVING SHOWER 24 HOURS AFTER BUILD ALLOWING SEALENT TO CURE

 

With all connections tight, the waste and hoses checked, jets fully sealed, your shower still around 18 inches 

from its designated final resting point and the silicone fully cured (hence leaving for 24 hours minimum) 

Switch on the overhead shower NOT the massage jets, remember these will fire water out at you and are 

not suitable for checking leaks as they would normally only operate when a person is in front of them. Just 

use COLD water setting as hot will make cabin misty and condensate thus the inspection becomes very  

difficult. Now on the OUTSIDE of the shower inspect each joint, factory seal, hose, clip and jet by walking 

from one side and going around to the back and then to the other side finishing at the front. If you have a 

small leak (normally caused through insufficient sealer or air bubble on assembly, dry the area thoroughly 

and reseal on the OUTSIDE. Please remember where you see the water this may not be exactly where the 

leak is as it could have run around to a low point. Never seal your inner fittings (accessories) inside unless 

you feel it necessary and make sure it is thin and neat, remember you will see this for the life of the shower! 

Again leave to cure and check. If all good now check shower functions i.e. jets for back massage,            

foot massage, (if you have one) and finally hand shower, check your joints to these functions at the rear 

again. Never use the shower until 

all

 checks have been made and the installer is 100% happy in the 

knowledge no leaks are present. 

 

All good?

 

Now push your shower FROM THE BASE NEVER GLASS OR FRAME into its final resting position.       

Now you can shower in the knowledge that you have no leaks a job done well and long product life. 

 

Happy showering!

 

Summary of Contents for GT8002a

Page 1: ...ier s details and your postcode to hand before calling Replacements Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warrant...

Page 2: ...cal Requirements What s In The Boxes Screw Pack Contents Plumbing Requirements Starting The Installation Electric Box Connections Steam Generator Connections Sealing and Water Testing MK117 Control Pa...

Page 3: ...ny years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your f...

Page 4: ...WHEN YOUR ITEM IS ASSEMBLED ALWAYS USE THE SERVICES OF A FULLY QUALIFIED ELECTRICAL COMPANY TO COMPLETE CONNECTION FROM SHOWER TO HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY...

Page 5: ...wo methods 1 Connect within current laws and IP directives using plug and RCD provided with steam version or supply one for non steam version 2 Preferred Wire into isolated fused feed connecting direc...

Page 6: ...use the word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit apart and carry...

Page 7: ...ent missing parts can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Product Code Descriptio...

Page 8: ...s Warranty is void if so as damage will occur If you have a combi supply please use a pressure reducing valve if required to lower the BAR pressure to the shower Please Remember that this product is f...

Page 9: ...ensure the correct sealing and alignment is carried out In the side of the waste supplied in the optional fitting kit you will notice a spigot not seen on an ordinary waste In most cases this is blan...

Page 10: ...re handed and can only fit one way Now place your completed front frame on the front of the shower tray as per the image on the right IMPORTANT When fitting the top rail ensure the wires from the colu...

Page 11: ...repeat for the other side Step 5 Now you have locked the two back panels in position align the back panels to the central column Once you are happy with the alignment apply silicone to the bottom of...

Page 12: ...umn lights here ready to connect later if a small gap exists silicone seal later Step 7 Fit the adjustable wheels to the top and bottom of the glass doors and ensure the wheels are at their lowest pos...

Page 13: ...ot massage retaining knobs to your glass back panel along with your chrome water outlet as shown in the above image To hang the foot massager itself to the wall push the massager onto the retaining kn...

Page 14: ...un clear silicone around the rear side of the probe to keep it securely in position Ozone o3 Unscrew the chrome pepper pot end and drop the white box upside down into the rear hole as shown in the ima...

Page 15: ...f the valve as shown Device output may differ from the image Please refer to your outer chrome faceplate in side your Insignia shower as a reference point IF YOUR DIAL DOES NOT CORROSPOND TO THE APPRO...

Page 16: ...and 2 x black together and tighten securely in to the connection block 3 Locate the other end of the wire with the 2 connect ors on 1 x male and 1 x female and plug the female end up to the correspond...

Page 17: ...ect the end with the single connection to the light on the roof of the shower as shown in the image 2 Locate the 2 other connections on the at the oppo site end and connect one end to the tray lights...

Page 18: ...www insigniarange com Last Modified 07 10 2015 18 Electric Box Steam Generator Connections Fan Speaker Ozone Light Light 2 Thermostatic Probe RJ11 Phone Connection Radio Aerial AUX Audio In Connection...

Page 19: ...shower Make sure these are fitted in the correct position as they are only attached for transportation reasons only Water Inlet Connect a braided hose from the shower valve s centre feed to this open...

Page 20: ...g around to the back and then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area thoroughly and reseal...

Page 21: ...select down manual search Button 8 TUN Switch Between manual auto radio searching Button 9 Up Arrow Channel select up manual search up Button 10 Alarm Activate Alarm Button 11 M Set Steam Time Temper...

Page 22: ...ww insigniarange com Last Modified 07 10 2015 22 Need Help If so then simply download Insignia s free comprehensive help and troubleshooting brochure now Simply visit www insigniarange co uk help aspx...

Page 23: ...eaker cover SP164 MK117 Control panel SP190 Blister pack SP152 Standard shower head Sp166 Approximately 4 meters of U Style seals SP057 90 Degree Chrome Water Inlet for foot massager SP214 Centre colu...

Page 24: ...used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All...

Reviews: