background image

 

www.insigniashowers.com

 

Last Modified: 20/09/2021

 

 09 

Twist to adjust

 

Step 1 —

 

Level the Tray and connecting the waste

 

 

 

NOTE: FOR STEAM SHOWERS ONLY:

 

Check the Spigot is drilled out prior to 
fitting. If it isn

t ensure you drill it out!

 

Summary of Contents for 1050

Page 1: ...upport Call 01908 317512 and request technical support for aiding your installation Replacements Parts Inside of your warranty period visit https www insigniashowers com click support and make a warranty claim Spares Replacements Parts Outside of your warranty period visit https www insigniashowers com replacement parts html WARRANTY REG NO _______________________ To claim your full 5 year warrant...

Page 2: ...the AMI System 16 Installing the Column 17 Installing the Front Right Corner Upright 18 Installing the Right Side Panel 20 Installing the Right Back Panel 22 Installing the Door Handles Seals and Magnets 23 Installing the Roof 24 Installing the Fixed Glass Panel 25 Installing the Seals 26 Installing the Accessories 27 Installing the Door Wheels 28 Water Valve Connections 29 Control Panel Connectio...

Page 3: ...on Assistance Looking for assistance with the Install GREAT NEWS We have our easy to follow Installation videos live online NOW to make your installation process easier than ever before Simply click the link below and watch the installation process Shower Install ...

Page 4: ...d this booklet with great care to ensure you get the best out of your build and have a shower that will last for many years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your finish ...

Page 5: ...e build up may cause damage to your shower and will not be covered under warranty TIP 3 Installation These showers are designed to be free standing and movable from their location should you have the need to replace anything ALWAYS USE Flexible braided water inlet pipes not supplied and not central heating plastic type Get your WRAS Approved Flexible Braided Hoses here www insigniashowers com wras...

Page 6: ...www insigniashowers com Last Modified 20 09 2021 06 ...

Page 7: ...plied Suitable McAlpine type 40 mm compression coupling for waste to house connection 2x Braided hoses not supplied Steam version requires 3 If you haven t purchased these already simply click the following link below or copy in to any web browser For ease we have listed the required pack below for your install Shower cabins with steam require pack 2 https www insigniashowers com wras approved bra...

Page 8: ...tings 1 Screw Pack Contents Product Code Description Quantity SP097 Door Handle 1 SP276 SP276A Twin Door Wheels Non Push Twin Door Wheels Push button 2 2 ST8 8mm Screws 12 ST10 10mm Screws 12 ST16 16mm x 3 5mm Screws 8 ST16 16mm x 4mm Screws 6 ST20 or WN20 20mm Nut and Bolt or Wing Nut 12 AMI01 Jubilee Clip For steam version only 1 SW9 Small Washers 20 DB9 Drill Piece 1 VERY IMPORTANT Have you got...

Page 9: ...howers com Last Modified 20 09 2021 09 Twist to adjust Step 1 Level the Tray and connecting the waste NOTE FOR STEAM SHOWERS ONLY Check the Spigot is drilled out prior to fitting If it isn t ensure you drill it out ...

Page 10: ...www insigniashowers com Last Modified 20 09 2021 10 Step 2 Connecting the framework Wider rail on top Narrow rail at the bottom 1 2 3 Internal View Framework securing clips x4 ...

Page 11: ...www insigniashowers com Last Modified 20 09 2021 11 Step 3 RubberGum the tray Apply RubberGum to raised sections of the tray and remove backing paper ...

Page 12: ...www insigniashowers com Last Modified 20 09 2021 12 Step 4 Connecting the left back panel to left side panel ST10 x6 DO NOT SCREW BACK PANELS TO THE TRAY PRESS PANELS DOWN FIRMLY ON TO THE RUBBERGUM ...

Page 13: ...www insigniashowers com Last Modified 20 09 2021 13 Step 5 Connecting the left corner upright to the side panel Internal View ...

Page 14: ...www insigniashowers com Last Modified 20 09 2021 14 Step 5 Connecting the left corner upright to the side panel continued ST16 3 5 x3 DB 9 ...

Page 15: ...www insigniashowers com Last Modified 20 09 2021 15 Step 6 Connecting the framework into the upright ST16 4 x3 DB 9 ...

Page 16: ...rsion it may already be fitted If it is please skip this step Place in middle hole first Turn Tri Jet to tighten Use Allen key to tighten left chrome outlet Use Allen key to tighten right chrome outlet Note Connect the 1 metre insulated hose to the back of the Tri Jet outlet to the steam out on the generator ...

Page 17: ... insigniashowers com Last Modified 20 09 2021 17 Step 8 Column Connection Rear View attach nuts and bolts or wing nuts from rear Below diagram shows the nut bolt install SW9 x 12 ST20 x 12 or WN20 x 12 or ...

Page 18: ...www insigniashowers com Last Modified 20 09 2021 18 Step 9 Corner post to framework connection ...

Page 19: ...www insigniashowers com Last Modified 20 09 2021 19 ST16 4 x3 DB 9 Step 9 Corner post to framework connection continued ...

Page 20: ...www insigniashowers com Last Modified 20 09 2021 20 Step 10 Connecting the right side panel ...

Page 21: ...www insigniashowers com Last Modified 20 09 2021 21 Step 10 Connecting the right side panel continued ST16 3 5 x3 DB 9 ...

Page 22: ...www insigniashowers com Last Modified 20 09 2021 22 Step 11 Connecting the right back panel ST10 x6 SW9 x 12 ST20 x 12 or WN20 x 12 or ...

Page 23: ...com Last Modified 20 09 2021 23 Step 12 Fitting door handle seals and magnets Slide magnetic seal into channel Ensure the flat side of the magnet faces out towards the door Once in position trim down so the roof sits flush ...

Page 24: ...www insigniashowers com Last Modified 20 09 2021 24 Step 13 Connecting the roof 1 ST8 x4 ...

Page 25: ...www insigniashowers com Last Modified 20 09 2021 25 Step 14 Fixed Glass Connection ST16 3 5 x2 DB 9 ...

Page 26: ...www insigniashowers com Last Modified 20 09 2021 26 Step 15 Fitting the seals 7mm Seal 12mm Seal 12mm 7mm Fit the seals inside the shower ...

Page 27: ...www insigniashowers com Last Modified 20 09 2021 27 Step 16 Accessories Installation Slide cover off Slide cover off ...

Page 28: ...dified 20 09 2021 28 Step 17 Fit top door wheels x 2 Slide cover off Door Tighten to secure wheels into door runners DO NOT OVERTIGHTEN Step 18 Fit bottom door wheels x 2 Slide cover off Door Step 19 Fitting the doors Slide covers on ...

Page 29: ...iashowers com Last Modified 20 09 2021 29 Monsoon Head Jets Cold Water Inlet Hot Water Inlet Outlet for Steam version only Step 20 Valve Water Connections Hand Shower 2 x Washers located on the back of the valve ...

Page 30: ...www insigniashowers com Last Modified 20 09 2021 30 Step 18 Control Panel Connections Power Supply ...

Page 31: ...eam generator there are 2 options available Purchase Insignia s WRAS approved braided hoses different packs are available for different shower types Install a static water line from the shower valve middle feed to the steam generator Even with a static water line flexible hosing will still be required for the hot and cold water feeds If you choose this option please ensure you purchase the correct...

Page 32: ...en take the hose connected to the steam drain and trim to a desired length Image 1 Once trimmed connect the hose to A Image 2 and secure in place with a jubilee clip from the screw pack contents Drill Out the spigot Image 3 on the waste and connect a hose from your accessory box from the spigot C to B and tighten using the jubilee clip provided A 1 2 NOTE MUST DRILL OUT B C 3 ...

Page 33: ...dy jets water will shoot towards the open doors and the user 3 Do not aim the hand shower directly at the joints of your shower as this does not fall under normal showering conditions However due to Insignia s unique design of the shower tray water will only leak back in to the tray so you won t get flooded 4 Visually check the water flow in to the waste and adjust the feet of the tray accordingly...

Page 34: ...accidentally activated Other buttons will remain functional whilst in this state of lock mode Button 5 Music Press once for FM Radio and press twice for Bluetooth For tuning radio stations or connecting Bluetooth please see the next page For volume control once on the radio or Bluetooth setting press Mode button 3 then use the left and right arrows to change the volume The volume is denoted by a n...

Page 35: ... Step 1 To tune your radio channels firstly press the music function button which looks like a musical note Tuning your radio channels Step 1 To connect a device via Bluetooth press the music function button twice which looks like a musical note the control panel will then show INS Step 2 Then once the radio is on press and hold the mode button until it starts scrolling Step 3 Finally once the pan...

Page 36: ...Glass Seals 7mm SP407 LeakFree Framework Securing Clip Black SP018A Water Valve Black Selection Plate SP018B Black Water Valve Water Flow Plate SP018C Black Water Valve Temperature Selection Plate Part Code Part Description SP333 Monsoon Shower head SP078 Ozone Module SP174 SP174a Round Body Jet Two Open Ends Round Body Jet One Open End SP236 SP112 warranty SP120 warranty Complete riser bar Shower...

Page 37: ...ore use 8 If you have any underlying health conditions which you feel could be aggravated by using a steam room consult your GP before use 9 If you begin to have any issues with your health after using a steam room stop immediately and consult your GP regarding your symptoms before continuing to use 10 Consult your GP before using the steam room if you re on medication at all especially with drows...

Page 38: ... bathroom ambient air temperature 4 To set the length you wish the steam to run for press the function button again 3 then use the arrows 4 to set your desired time The maximum length that can be set is 60 minutes 5 Only steam for approximately 10 15 minutes per session at your desired temperature Due to temperature your body can overheat dehydrate and cause light headedness This is very important...

Page 39: ...d in water until it is fully hydrated Pour at least 5ml half a bottle of the AMI essential oil onto the pad The more oil you use the more intense the aroma 3 Fully insert the diffuser pad into the allotted slot of the AMI Oil Diffuser Steam Guard and engage the steam function on your shower steam room to infuse the essential oil into the steam NEVER place or remove the pad from the diffuser whilst...

Page 40: ...www insigniashowers com Last Modified 20 09 2021 40 Bathroom Electrical Zones ...

Page 41: ...hroom goes past zones 0 1 and 2 portable electrical appliances can be utilised if their cord length doesn t allow them to be used in zone 2 For example a hairdryer can be used in the outside zones provided its extended length doesn t enable it to be used in zone 2 Despite the fact that installing electrical appliances past zone 2 is allowed without an IP number it is recommended that electrical ap...

Page 42: ...common crossed out wheelie bin label We accept returns of all products carrying the Insignia brand All other products are either considered outside the scope of WEEE or Insignia is not technically the producer of these products Insignia also accepts historic like for like WEEE returns All WEEE returned to Insignia will be recycled in appropriate treatment and recycling centres in accordance with t...

Page 43: ...www insigniashowers com Last Modified 20 09 2021 43 ...