30
INSTALLATION INSTRUCTIONS
IMPORTANT - SAFETY REQUIREMENTS
Where applicable Natural Gas and L.P Gas versions
of this appliance are available. Check that this
model is suitable for the type of supply available.
This appliance must be installed and/or serviced by
a competent person, in accordance with the Gas
Safety (Installation and Use) Regulations Current
Editions and the IEE Wiring Regulations. Detailed
recommendations are contained in the following
British Standards Codes of Practice - BS.5440: Par
2 and BS.6891. All British Standards must be
'Current Editions'.
This appliance must be installed by a
qualified electrician / competent person
(CORGI Registered). Safety may be
impaired if installation is not carried out
in accordance with these instructions.
Before connecting the appliance make
sure that the voltage of your electricity
supply is the same as that indicated on
the rating plate. This is situated on the
lower front frame of the appliance and
can be seen upon opening the door.
Alternatively the rating plate may also be
found on the back or top of some models
(where applicable).
Do not alter the electrical circuitry of this
appliance.
PROVISION FOR VENTILATION
This appliance is not connected to a combustion
products evacuation device. It shall be installed and
connected in accordance with the current installation
regulations. Particular attention shall be given to the
relevant requirements regarding ventilation.
The room containing the appliance should have an
air supply in accordance with BS.5440: Part 2
Current Edition. All rooms require an openable
window or equivalent and some rooms will require a
permanent vent as well. For room volumes up to
5m
3
an air vent of 100cm
2
is required: for room
volumes between 5m
3
and 10m
3
an air vent of 50cm
2
is required. If the room has a door that opens
directly to the outside, no air vent is required. For
room volumes that exceed 11m
3
no air vent is
required. If there are other fuel burning appliances
in the same room, BS.5440: Part 2 Current Edition
should be consulted to determine the requisite air
vent requirements.
Prolonged intensive use of the appliance may call for
additional ventilation, for example opening a window,
or more effective ventilation, for example increasing
the level of mechanical ventilation where present.
Summary of Contents for EKM6047
Page 1: ...Model EKM6047 ...
Page 35: ...NOTES 35 ...