![Inscape Data Link Power LPS3400ATMP-T1 User Manual Download Page 8](http://html1.mh-extra.com/html/inscape-data/link-power-lps3400atmp-t1/link-power-lps3400atmp-t1_user-manual_2065285008.webp)
Page | 8
Top Cover
To connect the wires, you are simply to open the top cover by the latch. To install and connect the wire,
please follow the connector assembly diagram on the next page. Please note the following IP weatherproof
rating, when close the top cover:
1.
Closing the top cover by latch, the weatherproof IP rating is IP66
2.
Closing the top cover by 4 screws, included in the package, the weatherproof IP rating is IP68
Please close the top cover based on the required weatherproof condition per your installation.
IP Web Management Login:
All network ports of this device support WEB management equipment, IP management by default 192.168.2.1,
subnet mask: 255.255.255.0, the default gateway: 192.168.2.254. The administrator of the PC as long as you can
communicate with the equipment management.
Default IP Address: 192.168.2.1
Default login
user
: “
admin
” and login
password
: “
system
”.
For more IP management details, please read IP Management User’s Manuel provided on the User’s CD
Control Panel Diagram
LED Indicator Description Table:
Indicator
Status
Description
SYS Indicator: POWER
Green LED ON
Power On, Normal
LED OFF
Power OFF
1000M Indicator: Link
OFF
No Connected PD or Power OFF
Yellow LED Blink Data transmission properly
Yellow LED ON
Connected with 1000Mbps network device
OFF
No connected PD
PoE Indicator: PoE
Green LED ON
Connected PD Device, working properly
Green LED Blink
Short circuit or current overload
OFF
No Connected PD or Power OFF
L/A Indicator: Link/Act
Green LED Blink
Data transmission properly
Green LED ON
Connection is OK and data is being sent and received.
OFF
No data connected
NOTE:
All PoE ports of PD devices are complying with IEEE802.3af standard