1.0  Introduction

The InPower SSC3 Series is a family of high current solid state DC contactors.  These contactors are available in 

current ratings of 200 and 300 amps, and are packaged plastic case with a metal baseplate.  As they have ex-

tremely low current draw when in the off state, they are ideally suited for use as load disconnect switches.  A key 

feature is the contactor’s highly efficient, low on-resistance, DC power switch.  This results in superior performance 

by producing a low voltage drop and generating only a small amount if internal heat.

The SSC3 family also incorporates LoadLogic technology which automatically compensates for different types of 

loads, starting up difficult loads, yet accurately detecting a dead short fault. It assists with starting up into resistive 

loads, inductive loads, capacitive loads, incandescent loads, and identifies dead short faults.

The status LED indicator is on when the SSC3 is ON (off when OFF), and flashes to indicate a fault shutdown.  

Automatic fault shutdown occurs for over-current, loss of ground, high/low-battery voltage, and/or over-

temperature.  In a fault condition the contactor is latched in the off state.  To reset the unit the faults must be 

cleared; then the control input voltage must be removed (<4.0V), then re-applied (>8.0V).  Removing the +BAT 

cable will also reset the unit.
The control INPUT and GND inputs utilize a 8-32 Threaded Terminals. The brass nuts on the INPUT and GND 

terminals shall be torqued to 4-5 inch lbs.  Connections for the high current DC cables utilize 3/8” - 16 brass bolts 

and copper washers with brass contact pads for low contact resistance.   Four 0.20” mounting holes allow for solid 

mounting  to a secure metal surface.

OWNERS MANUAL SSC3

Solid State Contactor Models:

SSC3-200A (200 Amps, 2 Lug)

SSC3-200B (200 Amps, 4 Lug)

SSC3-300 (300 Amps, 4 Lug)

InPower SSC3-200A Solid State Contactor

Ground

LOAD

Fuse

Battery

+

+12 Volt Loads

Ground

+12 Volts

Control Switch

Ground

Summary of Contents for SSC3

Page 1: ...ith starting up into resistive loads inductive loads capacitive loads incandescent loads and identifies dead short faults The status LED indicator is on when the SSC3 is ON off when OFF and flashes to indicate a fault shutdown Automatic fault shutdown occurs for over current loss of ground high low battery voltage and or over temperature In a fault condition the contactor is latched in the off sta...

Page 2: ...rational Temperature Range 40 o to 185 o F 40 o to 85 o C Over temperature Shutdown 185 o F 85 o C Operational Voltage Range 7 0 to 18 0 Volts Fault Reset Remove Voltage 4 0V and then reapply a voltage 8 0V if no faults exist LED Indicator Switch on LED ON Switch off LED Off Faults exist LED Flash INPUT Signal Voltage Range 8 0 to 18 0 Volts True ON 4 0 Volts False OFF Standby Current 3 8mA Enviro...

Page 3: ...mal ef ficiency the mounting surface should be a thick metal surface such as an aluminum plate 1 8 x 16 x 16 inches or larger To facilitate heat transfer please apply a thin layer of silicon thermal material user supplied to the metal plate on the bottom of the SSC3 Smooth this out with a flat edge to insure there are no gaps Secure the contactor to the flat metal surface using four screws and tig...

Page 4: ...K LOAD Ohms 0 20 INPUT BAT LOAD 12V 200 AMP SOLID STATE CONTACTOR 4 125 0 375 LED GND 2 375 4 125 3 40 2 50 1 688 1 125 3 125 3 775 0 75 0 875 Double Crimp Lugs Customer Supplied 0 813 1 4375 3 775 3 40 www InPowerLLC com Lot Code InPOWER the systems people SSC3 200A 7 0 18Vdc INPUT 8 0 18Vdc 0 625 Patented www InPowerLLC com Patents Electronic Switch 0 20 INPUT BAT LOAD 5 125 0 375 GND 4 125 3 77...

Reviews: