background image

 

 

 

 

 

 

       INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS 

 

 

CENTRIFUGAL PUMP 

 

PROLAC HCP 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Original Instructions 

 

01.030.30.05EN 

 

(0) 2021/01

0

1

.0

3

0

.3

2

.0

0

0

4

 

Summary of Contents for PROLAC 65-175

Page 1: ...INSTALLATION SERVICE AND MAINTENANCE INSTRUCTIONS CENTRIFUGAL PUMP PROLAC HCP Original Instructions 01 030 30 05EN 0 2021 01 01 030 32 0004...

Page 2: ...5 175 PROLAC HCP 65 215 PROLAC HCP 65 250 PROLAC HCP 80 175 PROLAC HCP 80 205 PROLAC HCP 80 240 From serial number IXXXXXX to IXXXXXX 1 XXXXXXXXXIIN to XXXXXXXXXIIN 1 Fulfills all the relevant provisi...

Page 3: ...rt and storage 8 5 4 Location 8 5 5 Adjustable legs 9 5 6 Pipes 9 5 7 Pressurisation tank 9 5 8 Electrical installation 10 6 Start up 6 1 Checks before starting the pump 11 6 2 Checks when starting th...

Page 4: ...mediately and lawfully and additionally INOXPA will be compensated for any civil liability claims submitted by third parties in the following cases the service and maintenance work has not been carrie...

Page 5: ...an the specified limit values be exceeded NEVER touch the pump or the pipework during operation if the pump is being used for transferring hot liquids or during cleaning The pump contains moving parts...

Page 6: ...l rule PROLAC HCP pumps in their standard version are used in the food industry mainly to transfer liquids For each type of the pump the hydraulic performance is given by the choice of impeller diamet...

Page 7: ...uctions manual instructions and service manual of the motor1 Unpack the pump and check the following the suction and discharge connections of the pump removing any rest of packaging materials the pump...

Page 8: ...tions to consult dimensions and weights During the transport disassembly or assembly of the pump there is a risk of loss of stability and that the pump could fall down and cause damages to the operato...

Page 9: ...pump as close as possible to the suction tank and whenever possible below the liquid level or even below the tank level in order to achieve the largest possible static head for suction Install suppor...

Page 10: ...operators or cause irreparable material damage Before handling the pump make sure that the motor is stopped Connect the motor in accordance with the instructions supplied by the motor manufacturer in...

Page 11: ...d on the motor plate Check that the direction of rotation of the motor is the right one 6 2 CHECKS WHEN STARTING THE PUMP Check that the pump is not making any strange noises Check if the absolute inl...

Page 12: ...Start up 12 INOXPA S A U 01 030 30 05EN 0 2021 01 Use special protection when the sound pressure in the operation area exceeds 85 dB A...

Page 13: ...rged Purge or fill Cavitation Increase the suction pressure The pump sucks in air Check the suction line and all of its connections Suction pipe obstructed Check the suction line and the filters if av...

Page 14: ...cted through the mechanical seal replace it following the instructions in chapter 8 7 Disassembly and assembly of the pump 8 3 MAINTENANCE OF THE SEALS SEALS REPLACEMENT Preventive maintenance Replace...

Page 15: ...n place The process of sterilization with steam is applied to all the equipment including the pump Do NOT start the pump during the process of sterilization with steam The parts materials suffer no da...

Page 16: ...es cause by a failure to comply with the instructions in this manual Preparation Provide for a clean working environment so some parts including the mechanical seal require very careful handling and o...

Page 17: ...mpeller 02 8 Manually remove the stationary part of the seal 08 which is located in the pump cover 03 9 If the thrust washer and the seal spring need to be replaced loosen the allen screws 51A that se...

Page 18: ...p cover 03 Remove the spring and thrust washers 4 Manually remove the stationary part of the secondary seal 08 which is located in the double seal cover 10 as well as the O ring 80C 5 Loosen the set s...

Page 19: ...assembly 1 Loosen the allen screw 51E on the shaft clamp 17 2 Remove the shaft 05 along with the clamp 17 Assembly 1 Mount the pump shaft 05 with the clamp 17 on the motor shaft 2 Tighten the allen sc...

Page 20: ...With the help of a thickness gauge move the pump shaft so that the impeller is located at the required distances B from the pump casing 01 0 4 mm for 40 110 40 140 50 150 65 175 y 80 175 and 0 5 mm f...

Page 21: ...t Other gaskets NBR Other materials for the seal consult with INOXPA External surface finish matt Internal surface finish Polished Ra 0 8 m Mechanical seal Type Internal single or double seal balanced...

Page 22: ...P 40 150 63 75 HCP 40 205 70 84 HCP 50 150 71 84 HCP 50 190 78 92 HCP 50 260 70 84 HCP 65 175 72 85 HCP 65 215 78 92 HCP 65 250 79 93 HCP 80 175 77 90 HCP 80 205 80 94 HCP 80 240 77 91 It must be born...

Page 23: ...C mm HCP 40 110 514 270 369 HCP 40 150 539 270 389 HCP 40 205 749 380 490 HCP 50 150 618 330 468 HCP 50 190 752 380 523 HCP 50 260 1018 465 637 HCP 65 175 781 380 518 HCP 65 215 1017 465 632 HCP 65 25...

Page 24: ...haft 1 AISI 316L 07 Motor leg 2 AISI 304 07A Adjustable leg 4 AISI 304 08 Mechanical seal 1 09 Seal cover 1 AISI 316L 14 Shroud 1 AISI 304 15 Clamp pump casing 1 AISI 304 17 Clamp motor 1 AISI 304 45...

Page 25: ...l nut 4 A2 54A Hexagonal nut 4 A2 80 O ring 1 EPDM 80A O ring 1 EPDM 80B O ring 1 EPDM 93 Motor 1 9 5 DOUBLE MECHANICAL SEAL Position Description Quantity Material 08A Double mechanical seal 1 10 Doub...

Page 26: ..._____________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________...

Page 27: ..._____________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________...

Page 28: ...nyoles Spain Tel 34 972 575 200 Fax 34 972 575 502 How to contact INOXPA S A U Contact details for all countries are Continually updated on our website Please visit www inoxpa com to access the inform...

Reviews: