Safety
INOXPA S.A.U.
03.600.30.02EN
·
(A) 2022/08
7
3. Safety
3.1. WARNING SYMBOLS
Safety hazard for people in general and/or for equipment
Electric hazard
Important instruction for the protection of the equipment and its functions
3.2. GENERAL SAFETY INSTRUCTIONS
Read the instruction manual carefully before installing and starting the mixer. Contact INOXPA in
case of doubt.
3.2.1. DURING THE INSTALLATION
Always take into account the
Technical Specifications
of
chapter 9
.
The installation and use of the mixer should always be in accordance with applicable regulations in
regard to health and safety.
Before starting up the mixer, check that it is properly anchored and its shaft is perfectly aligned.
Incorrect alignment and/or excessive stress during coupling can cause serious mechanical problems
in the mixer.
Take all possible precautions when lifting the mixer. Always use properly attached slings when
moving the mixer with a crane or other lifting device.
Keep the motor and the switchboard under control, particularly in areas where there is a risk of fire
or explosion.
When cleaning, do not spray directly on the engine.
Do not disassemble the mixer until the switchboard has been disconnected. Remove the fuses and
disconnect the power cable supplying the motor.
All electric work should be carried out by specialised personnel.
3.2.2. DURING OPERATION
The
Technical Specifications
of
chapter 9
should always be observed. Under no circumstances can
the specified limit values be exceeded.
Before starting up the mixer, remove all the tools used during the assembly.
Do not open the tank while the mixer is in operation.
Do not operate the mixer when the rotating parts are not equipped with their guards or are not
properly assembled.
If the mixer operates in an open bank, the safe distances of the moving parts should be in accordance
with EN ISO 13857:2019.
The mixer has rotating parts. Do not place hands or fingers in the mixer while it is operating. This
may cause serious injuries.
Do not touch the parts of the mixer that are in contact with the fluid when in operation. When the
mixer operates with hot fluids (temperatures above 50ºC), skin burning is risky. In such cases,
collective protection means (in this order or priority: separation, protective screen, heat-insulating
material) or, in the absence of this, personal protection gear (gloves) must be used.
ATTENTION