INOXPA ASPIR A-150 Installation, Service And Maintenance Instructions Download Page 6

General Information 

 

   

 

 

INOXPA S.A.U.

 

· 01.400.30.09EN · (0) 2021/04 

4. General Information 

4.1.  DESCRIPTION 

The ASPIR pump has a compact construction, monoblock and vertical aspiration and impulse.  

The ASPIR pump is made of a cold-formed stainless steel discharge casing, suction casing, diffuser and lantern 
built  by  stainless  steel  investment  casting,  star-shaped  fixed  impeller  and  an  external  mechanical  seal  that 
prevents any contact of the spring with the product. 

The  standard  IEC  motor  of  type  IM  B35  is  protected  by  a  stainless  steel  shroud  and  provided  with  height 
adjustable hygienic designed legs in stainless steel too. 

 

4.2.  OPERATING PRINCIPLE 

The impeller is housed between the suction casing and the diffuser and it rotates in conjunction with the pump 
shaft.  This  arrangement,  together  with  the  rotation  of  the  impeller  and  the  arrangement  of  the  side  channel, 
creates  a  negative  pressure  inside  the  suction  casing,  which  generates  the  suction  force  of  the  pump.  At  the 
same  time,  the  fluid  receives  energy  in  the  form  of  kinetic  energy  and  pressure  energy,  and  this  impels  it 
through the discharge casing. 

 

4.3.  APPLICATION 

ASPIR  pump  is  a  sanitary  side-channel  self-priming  pump  suitable  for  use  in  the  food-processing, 
pharmaceutical and chemical industries. 

It is specially designed for pumping products containing air or gas, and it can also be used for  negative suction 
with prior priming  as well as in filtration  equipment. It  can be used to pump wine, oil, syrups, volatile  products 
such as alcohol, acetone and other solvents or products at temperatures close to the boiling point. 

However, the main use of this pump is for CIP return. 

For each type of pump, the hydraulic performance is given by the choice of impeller diameters and speeds. The 
characteristic curves also show the power and NPSH requirements. The intended use of the pump is defined by 
its characteristic curve and operating limits provided in the 

9. Technical Specification

s

 

 

 

The range of application for each type of pump is limited. The pump was selected for a given set of 
pumping  conditions  when  the  order  was  placed.  Misuse  of  the  pump  or  its  use  beyond  the 
operating limits may be dangerous or cause permanent damage to the equipment.   INOXPA shall 
not be liable for any damage resulting from the incompleteness of the information provided by the 

purchaser (nature of the fluid, rpm, etc.). 

 

 

ATTENTION 

Summary of Contents for ASPIR A-150

Page 1: ...INSTALLATION SERVICE AND MAINTENANCE INSTRUCTIONS SIDE CHANNEL PUMP ASPIR Original Instructions 01 400 30 09EN 0 2021 04 01 400 32 0005...

Page 2: ...From serial number IXXXXXX to IXXXXXX 1 XXXXXXXXXIIN to XXXXXXXXXIIN 1 Fulfills all the relevant provisions of the following directive Machinery Directive 2006 42 CE Regulation EC n 1935 2004 Applica...

Page 3: ...l seal with quench 9 5 7 Electrical installation 10 6 Start up 6 1 Checks before starting the pump 11 6 2 Checks when starting the pump 11 7 Troubleshooting 8 Maintenance 8 1 General considerations 14...

Page 4: ...ns failure of specific maintenance and repair procedures possible electrical mechanical and chemical hazards risk to the environment due to the type of substances released 2 3 WARRANTY The conditions...

Page 5: ...s can the specified limit values be exceeded NEVER touch the pump or the pipework during operation if the pump is being used for transferring hot liquids or during cleaning The pump contains moving pa...

Page 6: ...gh the discharge casing 4 3 APPLICATION ASPIR pump is a sanitary side channel self priming pump suitable for use in the food processing pharmaceutical and chemical industries It is specially designed...

Page 7: ...uctions manual instructions and service manual of the motor1 Unpack the pump and check the following The suction and discharge connections of the pump removing any rest of packaging materials The pump...

Page 8: ...Specifications to consult dimensions and weights During the transport disassembly or assembly of the pump there is a risk of loss of stability and that the pump could fall down and cause damages to th...

Page 9: ...ligned with the pipework and have a diameter similar to that of the pump connections Place the pump as close as possible to the suction tank and whenever possible below the liquid level or even below...

Page 10: ...age Before handling the pump make sure that the motor is stopped Connect the motor in accordance with the instructions supplied by the motor manufacturer in accordance with the current national legisl...

Page 11: ...y pass option when it suction from a level below of the pump level the by pass will be closed why it will not suction 6 2 CHECKS WHEN STARTING THE PUMP Check that the pump is not making any strange no...

Page 12: ...04 Use special protection when the sound pressure in the operation area exceeds 85 dB A If the pump has not an incorporated a pressure by pass you should mount a relief valve or any other device that...

Page 13: ...suction line Pump not drained Drain or fill Cavitation Increase suction pressure Air is suctioned by the pump Check the suction pipe and all its connections Clogged suction pipe Check the suction pip...

Page 14: ...structions in the chapter 8 7 Disassembly and assembly of the pump 8 3 MAINTENANCE OF THE SEALS SEALS REPLACEMENT Preventive maintenance Replace after twelve 12 months We also recommend replacing the...

Page 15: ...tic cleaning process is not provided proceed to disassemble the pump as indicated in the chapter 8 7 Disassembly and assembly of the pump Check the concentration of the cleaning solutions Incorrect co...

Page 16: ...maged parts Tools Use the proper tools for assembly and disassembly operations Use them correctly Cleaning Before disassembling the pump clean it outside and inside NEVER clean the pump by hand when i...

Page 17: ...en installing the new seal use soapy water when fitting the different parts and gaskets to allow them to slide better Apply to the stationary as well as the rotating parts 8 7 3 Motor change 1 Firstly...

Page 18: ...the shaft with a new one Fix the shaft according the table of chapter 8 6 1 Disassembly of the pump and single mechanical seal 5 Assembly the suction cover 01 carefully to avoid damaging the lip seal...

Page 19: ...nical seal Type of seal single inside seal Material of stationary part graphite C standard silicon carbide SiC Material of rotating part silicon carbide SiC standard Seal material EPDM standard FPM Wa...

Page 20: ...kg IEC 80 100 112 132 160 kW 0 75 2 2 3 4 5 5 7 5 11 15 A 50 22 A 80 48 53 59 A 150 58 75 85 A 200 143 166 9 3 DIMENSIONS WITH WHROUD AND LEGS Pump type Motor Dimensions mm IEC A B C A 50 80 290 529 3...

Page 21: ...1 9 4 DIMENSIONS WITHOUT WHROUD AND WITHOUT LEGS Pump type Motor Dimensions mm IEC kW A B C A 50 80 200 422 220 A 80 100 261 568 265 112 261 590 291 A 150 112 4 265 590 291 132 5 5 300 640 332 7 5 300...

Page 22: ...Technical Specifications 22 INOXPA S A U 01 400 30 09EN 0 2021 04 9 5 EXPLODED DRAWING OF ASPIR PUMP 01 400 32 0015...

Page 23: ...1 08A Mechanical seal stationary part 1 14 Shroud 1 1 4301 AISI 304 15 Clamp body 1 1 4301 AISI 304 16 Diffuser 1 CF3M 35 Fixation impeller washer 1 1 4404 AISI 316L 47A Lantern protection 2 PETP 50...

Page 24: ...01 400 30 09EN 0 2021 04 9 7 MECHANICAL SEAL WITH QUENCH Position Description Quantity Material 05A Shaft for quench 1 1 4404 AISI 316L 88 Lip seal 1 92 Quick connector for tube D 8 2 1 4404 AISI 316...

Page 25: ..._____________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________...

Page 26: ..._____________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________...

Page 27: ..._____________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________...

Page 28: ...nyoles Spain Tel 34 972 575 200 Fax 34 972 575 502 How to contact INOXPA S A U Contact details for all countries are Continually updated on our website Please visit www inoxpa com to access the inform...

Reviews: