ENABLE ALL:
PROGRAM 4 ##
[Master, Sub-Master, Manager Code] (#) (4) [1-digit Bank Number] (#)
EXAMPLE:
Assuming that the current Master, Sub-Master or Manager Code is (1) (2) (3) (4) (5).
Press (1) (2) (3) (4) (5)
•
(#) (4) (3) (#)
••
NOTE: If Master or Sub-Master Code was used to unlock the unit prior to the program sequence,
all 100 User/Manager Codes are enabled. (Service Codes must be reprogrammed)
If the Manager Code was used to unlock the unit prior to the program sequence,
only the 9 users under that manager is enabled.
PASS TIME (DOOR UNLOCK):
PROGRAM 902-920
Pass time determines the amount of time between two key presses. It can be set between 2 to 20
seconds. Factory default is 5 seconds.
[Master/Sub-Master Code] (#) (9) [Value between 02 to 20]
EXAMPLE:
Assuming that the current Master or Sub-Master Code is (1) (2) (3) (4) (5) and you want to set the
Pass time to 7 seconds.
1. Press (1) (2) (3) (4) (5)
•
(#) (9) (0) (7)
••
2. Pass time is now set to 7 seconds.
09