background image

 

 

 

 

INOVONICS WARRANTY 

I

 

TERMS OF SALE:

  Inovonics products are sold with an under-

standing of “full satisfaction”; that is, full credit or refund will be is-
sued for products sold as new if returned to the point of purchase 
within 30 days following their receipt, provided that they are re-
turned complete, and in “as received” condition. 

II

 

CONDITIONS OF WARRANTY:

  The following terms apply unless 

amended 

in writing

 by Inovonics, Inc. 

A.  The Warranty Registration Card supplied with the product 

must

 

be completed and returned to Inovonics, or the Warranty regis-
tered online at www.inovonicsbroadcast.com, within 10 days of 
delivery. 

B.  The Warranty applies only to products sold “as new.”  It is ex-

tended only to the original end-user and may not be transferred 
or assigned without prior written approval by Inovonics. 

C. The Warranty does not apply to damage caused by misuse, 

abuse, accident or neglect.  This Warranty is voided by unau-
thorized attempts at repair or modification, or if the serial identi-
fication tag has been removed or altered.  

III

 

TERMS OF WARRANTY:

  Inovonics, Inc. products are warranted 

to be free from defects in materials and workmanship. 

A.  Any discrepancies noted within THREE YEARS of the date of 

delivery will be repaired free of charge, or the equipment will be 
replaced with a new or remanufactured product at Inovonics’ 
option. 

B.  Parts and labor for factory repair required after the three-year 

Warranty period will be billed at prevailing prices and rates. 

IV

 

RETURN OF GOODS FOR FACTORY REPAIR:

 

A.  Equipment will not be accepted for Warranty or other repair 

without a Return Authorization (RA) number issued by Inovon-
ics prior to its return.  An RA number may be obtained by call-
ing the factory.  The number should be prominently marked on 
the outside of the shipping carton. 

B. Equipment must be shipped prepaid to Inovonics.  Shipping 

charges will be reimbursed for valid Warranty claims.  Damage 
sustained as a result of improper packing for return to the fac-
tory is not covered under terms of the Warranty and may occa-
sion additional charges. 

Revised Sept. 2011 

 

 

 

 

5805 Highway 9  •  Felton, CA 95018 USA 
Tel: (831) 458-0552 • Fax: (831) 458-0554 

—— www.

inovonicsbroadcast

.com —— 

Serving the broadcast industry since 1972 

Summary of Contents for INOmini 673

Page 1: ...FM RDS Monitor Receiver Installation User Guide June 2019 Rev 1 0 0 0 Firmware www inovonicsbroadcast com 673...

Page 2: ...1 Tuning the Receiver 11 Carrier Strength and Alarm 12 Audio Muting 13 Signal to Noise and Multipath 13 FM Stereo Mode 14 Program Audio Metering 15 The Audio Loss Alarm 15 Headphone Monitoring 16 Audi...

Page 3: ...MHz 107 9MHz in 100kHz steps Antenna Input 75 ohm F Sensitivity SNR 10 V for 50dB monaural S N 35dB V for 70dB monaural S N IF Bandwidth Auto signal adaptive or manual selection of 110kHz 84kHz 60kHz...

Page 4: ...istration process Not only does registration assure coverage of the equipment under terms of the Warranty printed inside the back cover of this manual but the user automatically receives any specific...

Page 5: ...Section III of this manual covers the easy setup and programming in structions Headphone Jack The front panel mini phone jack will accommodate stereo headphones of virtually any impedance with a 3 5m...

Page 6: ...ainst a red background quite visible even across the room If you have not yet set up the unit for use the LOW SIGNAL and or the AUDIO LOSS alarms will begin to flash soon after the receiver is powered...

Page 7: ...ns A series of bars to the right of RF will give a rudimentary display of incoming carrier strength 12 If it is transmitting an RDS Radio Data System subcarrier once a station is tuned in the station...

Page 8: ...any thing concrete but certainly more is better Likewise MP gives a relative indication of multipath signal reflection effects that radio transmissions encounter on 14 their trip to the receiver whic...

Page 9: ...n lightly processed programming will have frequent peaks reaching toward 0dB or 100 16 modulation A setting of 10dB will probably suffice for nearly any programming format Be sure to push the knob aft...

Page 10: ...may take a short while to receive the RDS Time packet as it is not sent continuously 18 PTY and PTYN Menu Screen 11 The RDS PTY Program TYpe function identifies programming type or format in the US fr...

Page 11: ...ul in Europe where nationwide networks utilize a number of low power transmitters to cover the entire country In the US translators are some 20 times used to rebroadcast a station s program on another...

Page 12: ...LOSS on the front panel and activate the rear panel R terminal With PI Error alarm selection the INOmini 673 gives an alarm for a PI code mismatch between the received PI and a PI code entered into t...

Page 13: ...et functions From most normal navigational menus push and hold down the knob to access these top secret settings 24 Firmware Version Hidden Menu Screen 1 The 673 Firmware screen will apprise you of wh...

Page 14: ...op erating menu tree navigate back to Hidden Menu 1 show ing 673 Firmware and push the knob 26 Section IV UPDATING FIRMWARE Firmware Files INOmini 673 firmware updates are issued at no charge wheneve...

Page 15: ...For these reasons and also because of the small format of this manual we have dispensed with schematic diagrams servicing instructions and a listing of component parts Nevertheless our policy has alwa...

Page 16: ...s been removed or altered III TERMS OF WARRANTY Inovonics Inc products are warranted to be free from defects in materials and workmanship A Any discrepancies noted within THREE YEARS of the date of de...

Reviews: