6.13.19 168-04493-01 Rev A © Inovonics, 2019 - www.inovonics.com
5
From the main menu, highlight Point Status, and press enter to select. The
Register Point menu displays.
Figure 19
The Main Menu, Point Status highlighted
6.
All registered points display. Highlight the point for the end-device that
will be placed in this location, and press enter to select. The Point
Status Summary screen displays.
Figure 20
The Point Status Summary screen
The Point Status Summary screen contains the following information:
Point # The point number you’ve selected displays here along with the
signal level of the selected end-device. Good indicates a signal sufficient
for EchoStream functionality; Weak indicates a signal insufficient for
EchoStream functionality; N/S indicates no signal received.
Good displays when the signal margin is 4 decibels or more. Weak displays
when the signal margin is less than 4 decibels.
N/S displays when no recognizable message is received at all, no matter
how weak.
End-device transmission symbol: The end-device transmission symbol, *,
beats when the receiver is hearing a signal directly from a selected end-
device. When receiving a good signal, the end-device transmission symbol
beats approximately once a second, and the receiver beeps accordingly.
High-power repeater transmission symbol: The high-power repeater
transmission symbol, +, beats when the receiver is hearing a signal from
the selected end-device that has been passed on by a high-power repeater.
When receiving a good signal, the high-power repeater transmission
symbol beats approximately once a second.
Rcv Lvl Indicates the overall strength of messages received from the
selected end-devices and repeaters, in decibels.
Rcv Mar Indicates the signal margin of messages received from the
selected end-devices and repeaters, in decibels.
Msg# Indicates the total number of messages received, up to 999.
Batt Indicates the battery status of the end-device as either OK or Low.
7.
Press enter for more signal information. The Point Status Message
Count screen displays.
Figure 21
The Point Status Message Count screen
Act# Indicates the total number of activation messages received, up to 999.
An activation message is defined as a message that does not fall into the
Tmp, Res and Sup categories described below. For example, an alarm
message on a pendant transmitter would be displayed as an Act message.
Tmp# Indicates the total number of tamper messages received, up to 999.
Res# Indicates the total number of reset and restoral messages received,
up to 999.
Sup# Indicates the total number of supervisory messages received, up to
999.
8.
Press enter for more signal information. The Point Status Signal
Strength screen displays.
Figure 22
The Point Status Signal Strength screen
Dir Lvl Indicates the overall strength of messages received directly from the
selected end-device, in decibels.
Dir Mar Indicates the signal margin of messages received directly from the
selected end-device, in decibels.
1st Lvl Indicates the overall strength of first hop end-device messages
received by high-power repeaters, in decibels.
1st Mar Indicates the signal margin of first hop end-device messages
received by high-power repeaters, in decibels.
Lst Lvl Indicates the overall strength of last hop high-power repeater
messages received by the survey receiver, in decibels.
Lst Mar Indicates the signal margin of last hop high-power repeater
messages received by the survey receiver, in decibels.
9.
Repeat all steps for the next point on your site map.
10.
When the site survey is complete, press the EN1223SK and EN1210SK
on/off buttons to stop transmission.
11.
Press the EN4016SK power button to turn off the survey receiver.
5 Perform a Site Survey without using Survey
Transmitters
The survey receiver can be used to monitor the signal strength of any end-
device or high-power repeater in your EchoStream system.
1.
Register the end-device or high-power repeater you want to monitor.
• Refer to section 3.3, “Register End-Devices” to register an end-
device; refer to section 3.4, “Register High-Power Repeaters” to
register a high-power repeater.
2.
Place the survey receiver where your network coordinator or receiver is
normally located.
3.
Activate the end-device.
4.
Monitor signal strength.
• Refer to step 5 through 8 in section 4, “Perform a Site Survey using
Survey Transmitters” to monitor signal strength.
6 Specifications
Operating frequency 915-928 MHz (Australia), 921-928 MHz (New
Zealand) 902-928 MHz (USA)
Operating environment 0°- 60°C (32°- 140°F), 90% relative humidity, non-
condensing
Measurement ac/- 2dB @ 25°C (77°F), +/- 3dB @ 0°C - 60°C
(32°F-140°C).
Receiver type Frequency hopping spread spectrum
Battery life and ordering info EN4016SK: Eight hours of continuous use
with 1.5V, AA alkaline batteries.
Caution:
Changes or modifications to this unit not expressly approved by
Inovonics Wireless Corporation may void the installer's authority to operate
the equipment as well as the product warranty.
Note:
E-mail [email protected] for a copy of the CE Declaration of
Conformity.