Inovonics EN4016SK Installation And Operation Manual Download Page 1

6.13.19 168-04493-01 Rev A © Inovonics, 2019 - www.inovonics.com

EN4016SK Survey Receiver

Installation and Operation Manual

1 Quick Start

By following this procedure you can quickly configure the supplied 

equipment to perform a site survey. Review the main body of this manual 

for additional options, features and a more detailed startup process.

Note: 

If performing site surveys in Australia or New Zealand, the additional 

setup steps in the main body of this manual must be performed.

1.

Slide off the battery cover on the back of the EN4016SK survey 

receiver.

2.

Load four AA batteries into the survey receiver.

3.

Press the power button to turn on the survey receiver.

 Figure 1  

EN4016SK survey receiver

4.

Press the enter button to advance to Main Menu.

5.

Select Register Point on the Main Menu.

6.

Select Point 1 on the Register Point menu.

7.

Press the EN1223SK reset button.

 Figure 2  

EN1223SK survey transmitter (sold separately)

8.

Select Pendant. The survey transmitter should now be registered.

9.

Press the EN1223SK On/Off button. The transmit LED should begin to 

flash.

10.

Use the small flat-blade screwdriver to press the housing release tab on 

either end of the EN1210SK and separate the housing.

11.

Select Point 2 on the Register Point menu.

12.

Press the EN1210SK Reset button. The transmitter should now be 

registered.

 Figure 3  

EN1210SK survey transmitter

13.

Press the EN1210SK on/off button. The transmit LED should begin to 

flash.

14.

Place the survey transmitters where you plan to mount your network 

coordinator or receiver.

15.

Walk the receiver to the first point you plan to use a transmitter or a two-

way end device.

Note: 

Reversing the position of the end device and the high-power 

repeater will make the survey easier to perform. This equipment reversal 

will not affect the accuracy of the results.

16.

Press exit to return to the Main Menu.

17.

Select Point Status on the Main Menu.

18.

Select Point 1 or Point 2 to view signal information.

 Figure 4  

The Point Status Summary screen

Power 

Button

Enter 

Button

Exit 

Button

 Reset 

Button

 On/Off 

Button

Transmit 

LED

On/Off 

Button

Reset 

Button

Frequency 

Band 

Selection 

Pins

Transmit 

LED

Signal 

Quality

Transmission 

Symbols

Reviews: