1.27.21 357-00045-01 Rev A © Inovonics, 2021 - www.inovonics.com
2
5.
Use the included three mounting screws to mount the EN1263.
• To mount on the wall, see Figure 4.
• To mount in a corner, see Figure 5.
Note:
The black arrows represent recommended mounting screw
locations; the gray arrows represent optional mounting screw locations
should the recommended locations be unavailable.
Figure 4
Wallmount configuration
Figure 5
Cornermount configuration
6.
Install the battery per Figure 6.
Figure 6
Install the battery
2.3 Select Pulse Count
The pulse count options provides control for difficult operating
environments. Automatic pulse count is recommended for reliable
operation in environments subject to temperature fluctuation that can cause
false alarms. The single pulse count mode is more sensitive to minor
temperature variations, and should be used in sites where variant heat
sources will not cause alarms. Automatic pulse count is the factory default
because it allows more reliable operation in environments subject to
temperature fluctuation. To select pulse count:
1.
Press the tamper button five times within three seconds.
Figure 7
Press the tamper button
2.
Wait for the green LED to blink five times, then:
• Press the tamper button one time within three seconds to select single
pulse count.
• Press the tamper button two times within three seconds to select
automatic pulse count.
3.
Confirm your selection.
• The green LED will blink once to indicate single pulse count has been
selected; twice to confirm automatic pulse count has been selected.
2.4 Select Fixed/Variable Sleep Time
The sleep time jumper setting provides control for normal or high-traffic
operating environments. When set to fixed, if the EN1263 senses motion, it