1.27.21 357-00045-01 Rev A © Inovonics, 2021 - www.inovonics.com 

2

5.

Use the included three mounting screws to mount the EN1263.

• To mount on the wall, see Figure 4.
• To mount in a corner, see Figure 5.

Note: 

The black arrows represent recommended mounting screw 

locations; the gray arrows represent optional mounting screw locations 

should the recommended locations be unavailable.

 Figure 4  

Wallmount configuration

 Figure 5  

Cornermount configuration

6.

Install the battery per Figure 6.

 Figure 6  

Install the battery

2.3 Select Pulse Count

The pulse count options provides control for difficult operating 

environments. Automatic pulse count is recommended for reliable 

operation in environments subject to temperature fluctuation that can cause 

false alarms. The single pulse count mode is more sensitive to minor 

temperature variations, and should be used in sites where variant heat 

sources will not cause alarms. Automatic pulse count is the factory default 

because it allows more reliable operation in environments subject to 

temperature fluctuation. To select pulse count:

1.

Press the tamper button five times within three seconds.

 Figure 7  

Press the tamper button

2.

Wait for the green LED to blink five times, then:

• Press the tamper button one time within three seconds to select single 

pulse count.

• Press the tamper button two times within three seconds to select 

automatic pulse count.

3.

Confirm your selection. 

• The green LED will blink once to indicate single pulse count has been 

selected; twice to confirm automatic pulse count has been selected.

2.4 Select Fixed/Variable Sleep Time

The sleep time jumper setting provides control for normal or high-traffic 

operating environments. When set to fixed, if the EN1263 senses motion, it 