The EE1265 is a wireless, ceiling-mounted, four-element passive infrared 

(PIR) intrusion detector providing protection from intruders by pyro-sensor 

array. Micro-controller signal analysis with special technology for pulse 

processing increases immunity to interference, vibration, static, lightning, 

ambient temperature changes, and other common causes of false alarms.

Caution: 

The EE1265 needs one minute for stabilization after power up. 

During the stabilization period, the LED will blink twice per second, and the 

EE1265 will not be operational.

1.1 Inovonics Contact Information

If you have any problems with this procedure, contact Inovonics technical 

services:

• E-mail: [email protected].
• Phone: (800) 782-2709; (303) 939-9336.

1.2 EE1265 Internal Components

 Figure 1  

EE1265 internal components

1.3 What’s in the Carton

• Four drywall mounting anchors.
• Four mounting screws.
• Two selection jumper.
• Two 3.0V lithium batteries.

2 Installation and Startup

2.1 Installation Notes

• These products are designed to be maintained by professional 

security technicians.

• Products are tested for indoor use.
• All products should be manually tested weekly.

2.2 Install the Batteries

The EE1265 can accommodate two batteries for extra battery life, but only 

one is required for operation.

Note: 

When installing batteries, it is recommended that batteries are 

replaced in new pairs from the same manufacturer. 

To install batteries:

1.

Loosen the housing tamper lock screw.

 Figure 2  

Remove the housing cover and mounting bracket

2.

Install the battery included with the unit.

3.

Install an optional second battery.

4.

Press the 

Reset

 button to initialize the transmitter.

Note: 

You must press the 

Reset

 button each time a new battery is 

installed.

2.3 Enable EchoStream Select

To meet ETSI requirements, Inovonics has developed a new line of EE 

868MHz-only products.  These new 868MHz-only products are compatible 

with older systems that include EchoStream Select products. If you are not 

using any ES products in your current system, skip to 2.4, “Select PIR 

Sensitivity”; if you are using ES products in your current system, you will 

need to configure the transmitter.
To enable EchoStream Select compatibility:

5.

To enable compatibility with ES products, place a selection jumper on 

the ES selection pins.

Note: 

The selection jumper is included in the EE1265 hardware packet.

6.

Press the 

Reset

 button to initialize the transmitter.

Caution: 

When pressing the 

Reset

 button, make sure you don’t also touch 

the ES selection pins. Touching the ES selection pins while pressing the 

Reset

 button can inadvertently set the EE1265 to the wrong frequency 

band.

2.4 Select PIR Sensitivity

The pulse count selection pins provide control for difficult operating 

environments. Automatic pulse count is recommended for reliable 

operation in environments subject to temperature fluctuation that can cause 

false alarms. The single pulse count mode is more sensitive to minor 

temperature variations, and should be used in sites where variant heat 

sources will not cause alarms. Automatic pulse count is the factory default 

because it allows more reliable operation in environments subject to 

temperature fluctuation. If you are using automatic pulse count, skip to 2.5, 

“Select Fixed/Variable Sleep Time”; if you are using single pulse count 

mode, you will need to configure the transmitter.
To select PIR sensitivity:

7.

Place the jumper on the left two pins to select a single pulse count.

For product and installation videos visit us at 

www.inovonics.com/videos or use the QR 

code below.

A

Batteries

B

Tamper switch

C

Pulse count selection pins

D

Test LED

E

Reset button

F

Test button

G

ES selection 

pins

H

Test reed switch

I

Fixed/variable sleep time 

selection pins

A

I

H

B

D

F

G

E

C

Housing 

tamper lock 

screw

Remove 

the 

housing 

cover

Remove 

the 

mounting 

bracket

Reviews: