Inovonics EchoStream EE4232MR Installation And Operation Manual Download Page 3

4.2.20 357-05818-01 Rev A © Inovonics, 2020 - www.inovonics.com 

3

3.1 Default Transmitter Programming

3.2 Default Trouble Condition Programming

4 Access Levels

There are three levels of EE4232MR access available to users. Only the 

level 2 authorized user and level 3 authorized installer are able to access 

EE4232MR menus.

During normal operation there is no visual indication of system status or 

activity on the LCD of the EE4232MR receiver. Unless the level 2 

authorized user or the level 3 authorized installer enters a valid password, 

the LCD will remain completely blank. 
To enter either the level 2 authorized user or the level 3 authorized installer 

password:

1.

Press any button; P

ASSWORD

 displays.

• Once P

ASSWORD

 displays, the password must be entered within 60 

seconds; if it is not entered within 60 seconds, the attempt will be 

counted as an incorrect password.

2.

Use the 

Up

 and 

Down

 buttons to scroll through the numerals; press 

Enter

 to select.

• The 

Back

 button deletes the last character entered.

3.

Repeat step 2 for each numeral in the password.

4.

When all numerals in the password have been entered, press 

Enter

.

Note: 

If an incorrect password is entered, all EE4232MR buttons will lock 

up for 90 seconds. If five incorrect passwords in a row are entered, the 

receiver will send a tamper fault and log the event. The tamper fault will be 

cleared once the correct password is entered.

5 Level 2 Access

Note: 

The default level 2 authorized user password is 1234.

Level 2 authorized users have access to two menu options after entering 

their password: S

YSTEM

 T

EST

 and S

YSTEM

 S

TATUS

.

5.1 System Test

System test mode is used to perform a functional test of all of the 

transmitters programmed into the system. Upon entry into test mode, the 

receiver outputs will be cleared, and transmissions will not generate the 

defined outputs. System test mode will timeout after 30 minutes of 

inactivity.

Note: 

System test mode only tests transmitters; repeaters are not tested.

To perform a system test:

1.

Select S

YSTEM

 T

EST

 to enter system test mode.

2.

Activate each of the transmitters in the system.

Note: 

An activation from any condition of a multiple condition transmitter 

will satisfy the test requirement for the entire transmitter. For example, 

pressing any button on an EE1236D three-condition pendant will satisfy the 

test requirement for the entire transmitter.

3.

Use the 

Up

 and 

Down

 buttons to scroll through the transmitters.

• Transmitters which have not sent an activation signal will display only 

the point number.

• Transmitters which have sent an activation signal will display the point 

number followed by ****.

Transmitter Alarms

 Output

1, 11, 21, 31

1

2, 12, 22, 32

2

3, 13, 23

3

4, 14, 24

4

5, 15, 25

5

6, 16, 26

6

7, 17, 27

7

8, 18, 28

8

9, 19, 29

9

10, 20, 30

10

Condition

 Output

Tamper

11

Low Battery

12

Supervision Loss/Inactive

12

Line Power Loss

12

Access level

Access

Level 1

No menu access

Level 2

Can view system status indicators and enter 
system test mode as included in the following 
menus:

• S

YSTEM

 S

TATUS

 

• S

YSTEM

 T

EST

Level 3

Can view system status indicators, change 
receiver system parameters, and perform the 
receiver functions included in the following 
menus:

• P

OINT

 S

TATUS

• I

NSTALL

 & S

ERVICE

• S

ETUP

 P

OINT

• PW  P

ROT

 LED

S

• S

YSTEM

 T

EST

• F

ACTORY

 C

ONFIG

• S

ELECT

 L

ANGUAGE

• C

HANGE

 P

ASSWORD

• S

IGNAL

 S

TRENGTH

• D

ELETE

 P

OINT

• R

EGISTER

 X

MITTER

• E

VENT

 L

OG

• Event Log

Access level

Access

Reviews: