WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture at the service panel. All wiring 

connections must be made with the power OFF to avoid personal injury and/or damage to the switch.

A.

Up Push button

B.

Down Push button

C.

Load (Black)

D.

Lin

e

 (Black) - Line in

E.

N

eutral

 (White) - N

e

utral in 

Single switch wiring

1.

Shut off power to the circuit at circuit breaker or fuse box. IMPORTANT! Verify 

power is OFF to switch box before continuing.

2.

Remove wall plate.

3.

Remove the switch mounting screws.

4.

There are up to three screw terminals on the switch; these are marked

C.

Load — Black (connected to lighting)

D.

Lin

e

  — Black (connected to power)

E.

N

eutral

 — White

 

(N

e

utral)

5.

Observe Important Wiring Information 

 IMPORTANT!:  This switch is rated for and intended to only be used with copper wire. Wire Gauge Requirements

 Use larger wires suitable for at least 80° C for supplying Line (HOT), Load, Neutral connections.

 Wire strip length:

 For attachment to screw terminals: Strip insulation 1" ,  For attachment using the enclosure’s holes: Strip

insulation 5/8".

 insulation 5/8".

6. Connect the black wire that goes to the light to the terminal marked Load.
7. Connect the black wire that comes from the electrical service panel (Hot) to the terminal marked Lin.

8. Connect the white wire to the neutral terminal marked Nin (use jumper wire if needed).
9. Insert Switch into the switch box being careful not to pinch or crush wires.
10. Secure the Switch to the box using the supplied screws.
11. Mount the wall plate.
12. Reapply power to the circuit at fuse box or circuit breaker and test the system.
Basic Operation
The connected light can be turned ON/OFF in two ways,
1. Manually from the front button of the In-wall Switch

2. Remotely with a Z-Wave Controller
Manual Control
The Front button allows the user to:
Turn ON/OFF the connected fixture.
To turn the connected fixture ON: Press the Up push button.
To turn the connected fixture OFF: Press the Down push button.

2. Linking your Z-Wave device

Reset switch to factory default:

Please use your controller to remove the device from the network. To factory reset, toggle UP the switch 10x in a row when 

powered on. However, please only use this method if your controller is missing or inoperable.

 

Adding device into the network:

r

1.

Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network.

2.

Once the controller is ready to include your device, triple press the Up/Down push button to include it
in the network.

3.

Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize 
performance.

4.

The device is associated in the same group when it included in setting process.

 

Now you can control you

Z-

W

Waavvee  ddeevviiccee  aaccccoorrddiinngg  ttoo  ggrroouuppss,,  sscceenneess,,  sscchheedduulleess  aanndd  aauuttoom

maattiioonn  pprrooggrraam

mm

meedd..  IIff  yyoouurr  ccoonnttrroolllleerr      

Reviews: