-263-
7 Control Mode
7.9.5 Related Parameters
Index
6040h
Name
Control word
Setting
Condition
& Effective
Time
During
running &
Immediately
Data
Structure
VAR
Data Type Uint16
Access
RW Mapping
RPDO
Related
Mode
All
Value Range 0 to 65535
Default
0
Defines the control commands.
bit
Name
Description
0
Switch on
1: Valid, 0: Invalid
1
Enable voltage
1: Valid, 0: Invalid
2
Quick stop
0: Valid, 1: Invalid
3
Running
1: Valid, 0: Invalid
4
New set-point
0 -> 1: homing
1 -> 0: homing
8
Halt
0: Keep present running state
1: Halt
Index
6041h
Name
Status word
Setting
Condition
& Effective
Time
-
Data
Structure
VAR
Data Type Uint16
Access
RO
Mapping
TPDO
Related
Mode
All
Value
Range
-
Default
0
Shows the servo drive status.
bit
Name
Description
0
Ready to switch on
1: Valid, 0: Invalid
1
Switch on
1: Valid, 0: Invalid
2
Operation enabled
1: Valid, 0: Invalid
3
Fault
1: Valid, 0: Invalid
4
Voltage enabled
1: Valid, 0: Invalid
5
Quick stop
0: Valid, 1: Invalid
6
Switch on disabled
1: Valid, 0: Invalid
7
Warning
1: Valid, 0: Invalid
8
Manufacturer-specific Undefined
9
Remote
1: Valid, control word activated
0: Invalid
10
Target reached
0: Home not located
1: Home located
12
Homing attained
0: Home not found
1: Home found
13
Homing error
0: No homing error
1: Homing error occurs
15
Home find
0: Home not located
1: Home located