background image

Data code 19011295 A00

H100 Series Jiaolong Control Cabinet

Maintenance Guide

User Guide

Summary of Contents for Monarch H100 Series

Page 1: ...Data code 19011295 A00 H100 Series Jiaolong Control Cabinet Maintenance Guide User Guide...

Page 2: ......

Page 3: ...ep it properly for future maintenance reference Notes For illustration purpose the drawings in this user guide are sometimes shown without covers or protective guards Remember to install the covers or...

Page 4: ...arts 12 2 Cabinet Removal 13 2 1 List of Serviceable Parts 13 2 2 Tools 14 2 3 Removing the Monitoring Cabinet 14 2 3 1 Door Plate 14 2 3 2 Air Switch 15 2 3 3 Lightning Protection Board 15 2 3 4 Sock...

Page 5: ...Contents 3 2 4 6 Power Supply Board A 23 2 4 7 Drive Module 23 2 4 8 Fan 24 2 4 9 Terminal Block 24 2 4 10 Transformer 25 2 4 11 Contactors 26 2 4 12 AC Reactor 27...

Page 6: ...Revision History 4 Revision History Date Version Change Description November 2020 A00 First release...

Page 7: ...e safety pre cautions 4 Use this product according to the designated environmental requirements Damage caused by improper usage is not covered by warranty 5 Inovance shall take no responsibility for a...

Page 8: ...Do not remove any part of the equipment at power on Failure to comply will result in an electric shock Operation DANGER Do not touch any wiring terminals during operation Failure to comply will result...

Page 9: ...e inspection or parts replacement must be performed by only professionals Do not repair the equipment at power on Failure to comply will result in an electric shock Before inspection and repair cut of...

Page 10: ...dual current device RCD Install an RCD with rated action current not greater than 30 mA in the car top lighting and shaft lighting circuits for protection 3 High leakage current warning The equipment...

Page 11: ...mixing and insulation damage Run the signal cables and power cables separately Use shielded twisted pairs STPs as analog signal cables and ensure that the shielded cables are reliably grounded at one...

Page 12: ...nning Failure to comply will result in an electric shock The grounding terminal of the motor must be grounded Otherwise you will suffer an electric shock when touching the motor housing Inspection mai...

Page 13: ...de the control cabinet when the elevator is running 1 1 2 Daily Cleaning Items No Cleaning Item 1 Clean the control cabinet periodically 2 The IP rating of the control cabinet is IP20 Protect the cont...

Page 14: ...rd and PG card Additional fuse is provided in the control cabinet to prevent damage to the fuse in case of an emergency The service life of the air switch and contactor are 2 to 3 years and that of th...

Page 15: ...D EA9X310 Ex9NLE S 1PN C6 30mA Operating board Fuse 50CTT4AH250V 50CTT2AH250V 50CF 063H Monitoring board MCTC MB N1 Interface board MCTC KCB N1 ADO board MCTC SCB Drive cabinet Door plate Protective c...

Page 16: ...e 2 3 Removing the Monitoring Cabinet 2 3 1 Door Plate Removal procedure Unlock the door lock using the triangle key Pull the bottom of the door plate outwards Release the top of the plate from the ta...

Page 17: ...tch Figure 2 2 Steps to remove the air switch 2 3 3 Lightning Protection Board Removal procedure Remove the socket cover by unfastening the four M4x8 screws on the cover Disconnect the plug in termina...

Page 18: ...he socket and RCD Remove the socket and RCD M4x8 screws Locking cables Figure 2 4 Steps to remove the socket and RCD 2 3 5 Operating Board Removal procedure Remove the operating board by unfastening t...

Page 19: ...Fuse holder Captive screws Figure 2 6 Steps to remove the fuse 2 3 7 Monitoring Board Removal procedure Remove the monitoring cover by unfastening the four M4x8 screws on the cover Unfasten the four M...

Page 20: ...erface board M4x8 screws M4x8 screws Figure 2 8 Steps to remove the interface board 2 3 9 ADO Board Removal procedure Disconnect the plug in terminal on the interface board and remove the four M4x8 sc...

Page 21: ...plate from the tab when the angle between the plate and the cabinet is about 30 Remove the door plate NOTE A grounding cable is used to connect the bottom of the cabinet door and the drive cabinet Af...

Page 22: ...ve the protective cover 2 4 3 Insulation Barrier and PG Card Removal procedure Unfasten the two M3x10 screws Remove the insulation barrier Pull up the PG card the plug in terminal is on the drive boar...

Page 23: ...remove the insulation barrier and PG card 2 4 4 MCB Removal procedure Remove the two M4x8 screws and two M4 hex head cap screws Pull up the MCB Remove the insulation sheet on the MCB NOTE Keep the ins...

Page 24: ...ure Unfasten the three M3x10 screws pull up the hard wired terminal and remove the power supply board B Remove the electrical insulation paper of the power supply board NOTE Keep the electrical insula...

Page 25: ...silicone pad under the power supply board A needs not to be removed Before installing the power supply board make sure that it is in the position shown in the following figure M4x8 screws M5 hex head...

Page 26: ...out the drive module and disconnect the fan cable Unfasten the four M4x25 screws and remove the fan M4 25 Figure 2 17 Steps to remove the fan 2 4 9 Terminal Block Remove the terminal block by disconne...

Page 27: ...Cabinet Removal 25 2 4 10 Transformer Removal procedure Unfasten the four M4 retaining nuts Remove the transformer M4 nuts Figure 2 19 Steps to remove the transformer...

Page 28: ...bles Remove the contactors from guide rails by pushing them to the right NOTE As shown in the following figure the contactors from the top to the bottom are the shorting motor stator contactor brake c...

Page 29: ...12 AC Reactor Removal procedure Unfasten the four M4 retaining nuts Remove the AC reactor NOTE The AC reactor is provided only for 380 V drive cabinet M4 nuts Figure 2 21 Steps to remove the AC reacto...