SMC
4
Chlorinator Control Unit
Mount the control unit on a wall using the bracket on the back and the screws
provided. Choose a place for easy access and reading. The control unit can only be
placed at a maximum of 1.5 meters away from the electrolytic cell due to cable
length. Choose a place with good ventilation and protection from the rain and other
possible water leaks or splashing.
We recommend that you have an electrical safety circuit breaker
fitted to your swimming pool electrical circuit.
Connect the earth wire (yellow and green) of the 230 VAC power supply cable to
the earth of the swimming pool electric panel. Connect the phase (brown) and the
neutral (blue) to the output contacts of the pump contactor in such a way that the
chlorinator will be powered only when the pump is working. Connect the chlorinator
wires to non occupied contacts.
Do not use the contacts in use by the pump.
This will prevent the chlorinator to be electrically connected to the pump when the
contactor is switched off what could cause serious damage. Verify that the
chlorinator switches off itself when the pump stops. This operation should be
performed by a professional.
Cell housing
The cell housing must be installed in the return flow to the swimming pool and as
the last element the water goes through before returning to the pool: always after
the filter and any the heat pumps, solar panels, etc. Use special glue for rigid PVC
and wait until it
completely dries before inserting the cell.
4 INSTALLATION