background image

1

 

 

1. 

Features of Dual Mode Infrared Thermometer 
INV-EF100 

 

The INV-EF100 thermometer is able to measure both forehead and ear 
temperatures by detecting the infrared heat emitted by the respective 
areas. The forehead mode is activated by pressing the F1 button and the 
eardrum mode is activated by pressing the F2 button.   
 

Convenient and easy to use 

  Easy mode of operation – Take measurement with the press of a 

button 

  Can be used anytime – even when your child is asleep 

  Obtain reading faster than an oral thermometer and more comfortable 

than a rectal thermometer 

  Ergonomic design 

  Color coded display for fever detection 

 

Accurate and quick 

Utilize the latest infrared technology  –  accurate, precise and instant 
readings. 

 
Safe and hygienic 

  Unlike traditional thermometers, there is no glass or mercury that 

could pose as a potential health hazard. The thermometer is made up 
of ABS and TPR plastics, an infrared sensor, an infrared temperature 
measuring element, a microcomputer controlled circuit and a LCD 
screen. 

  BPA and latex free.   

 

Memory Recall 

Has a Memory Mode that can recall 20 previous readings to track 
changes in temperature. 
 

Convenient Fever warning 

When the temperature exceeds 99.5°F/37.5°C, the thermometer will 
warn the user that he/she may have a fever by 7 rapid short beeps and a 
flickering reading with a red backlit on the LCD screen for 3 seconds. (For 
normal body temperature, the signal is a long beep with a green backlit.) 
 
 

 

Summary of Contents for INV-EF100

Page 1: ...INV EF100 Dual Mode Digital Infrared Thermometer Instruction Manual Ver 1 1 ...

Page 2: ... in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Innovo Medical reserves the right of final interpretation of this document Version 1 1 Issuing Date June 2016 To download the latest manual for the thermometer simply scan the QR code above or visit http inn...

Page 3: ...nfancy to adulthood That is why the INV EF100 Dual Mode Digital Infrared Thermometer is designed to be BOTH an ear thermometer AND a forehead thermometer offering users the freedom to choose between two modes We recommend that you use the forehead measurement mode if your child is less than 1 yr old The eardrum measurement mode can be used when they are older and more comfortable with a foreign ob...

Page 4: ... 2 3 Care and Cleaning 3 4 Note on Body Temperature 5 5 Product Designs 6 6 Measuring Forehead Temperature 7 7 Measuring Temperature via Eardrum 7 8 Instructions for Display and Operation 9 9 Troubleshooting 12 10 Technical Specifications 13 11 Warranty and After Sale Service 16 12 Symbols 16 ...

Page 5: ...on Accurate and quick Utilize the latest infrared technology accurate precise and instant readings Safe and hygienic Unlike traditional thermometers there is no glass or mercury that could pose as a potential health hazard The thermometer is made up of ABS and TPR plastics an infrared sensor an infrared temperature measuring element a microcomputer controlled circuit and a LCD screen BPA and latex...

Page 6: ...hat you have a medical problem Do not use the thermometer for purposes not specified in this User Manual Follow the instructions stated herein and operate the thermometer carefully when measuring children s temperature Do not use the thermometer if any part especially the sensor shows any sign of damage Do not attempt to repair the thermometer Please contact your distributor The thermometer is not...

Page 7: ...eadings CAUTION Any debris and or facial oil on the sensor lens will prevent an accurate measurement Always check the sensor before use The lens should be reflective and gleaming If it looks dull and lackluster please clean the lens before use To clean the lens gently swab the surface with a cotton swab moistened with rubbing alcohol 70 Isopropyl Do not exert too much pressure as it may damage the...

Page 8: ...curate measurements Normal body temperature is a range and varies by site Therefore measurements from forehead and eardrum should not be compared directly In general an ear temperature is usually 0 5 1 F 0 3 0 6 C higher than an oral temperature whereas a forehead temperature is usually 0 5 1 F 0 3 0 6 C lower than an oral temperature Therefore it is NORMAL to get 1 2 F 0 6 1 2 C difference betwee...

Page 9: ... critical to know the individual s normal body temperature when he she is well Take multiple readings to obtain the normal body temperature range and note the specific body site measured for example forehead or eardrum temperature Body Site Normal Temperature Range Forehead 94 5 F 99 1 F 34 7 C 37 3 C Eardrum 96 4 F 100 4 F 35 8 C 38 0 C Mouth 95 9 F 99 5 F 35 5 C 37 5 C Armpit 94 5 F 99 1 F 34 7 ...

Page 10: ...rature and access Menu options 5 LCD display 6 Battery cover Normal body temperature fluctuates throughout the day and is also affected by external factors The body temperature of an individual is the lowest between 2 00 a m and 4 00 a m and the highest between 2 00 p m and 8 00 p m An individual s body temperature typically changes by less than 1 C 1 8 F each day ...

Page 11: ...ressing the F1 button at any time although it is recommended that you wait 10 seconds between readings Make sure that the forehead is free of hair and perspiration The probe cover is attached out of the box 7 Measuring Temperature via Eardrum 1 Gently remove the probe cover to reveal the ear probe 2 Insert the ear probe into the ear canal 3 Press and release the F2 button The temperature will be d...

Page 12: ...ok deceptively clean when it is not The lens of a clean sensor should be reflective and gleaming If it looks dull and lackluster then it is dirty Please clean the lens with a cotton swab moistened with alcohol and wait 5 10 mins for the alcohol to completely evaporate before using the thermometer 2 Please use the thermometer indoor or in an environment where there is no strong air draft 3 Do not m...

Page 13: ... temperature will be displayed on the LCD screen 2 Measurement of ear temperature Detach the probe cover Insert the ear probe into the ear canal Press and release the F2 button The temperature will be displayed on the LCD screen 3 To measure again simply press the F1 F2 button accordingly When the temperature is below 99 6 F 37 6 C 32 0 99 5 F 0 0 37 5 C there will be a long beep and a green backl...

Page 14: ...ress and hold button F2 for 3 6 seconds and the LCD will display with the M signal blinking None Press button F2 again and the LCD will display the number 1 with the M signal After 1 second the measured temperature with the mode of measurement icon will be displayed Note that this is the latest reading To recall the next recorded reading press button F2 again The number 2 with the M signal will be...

Page 15: ...F 40 0 C or drops below 50 0 F 10 0 C 3 short ticks and green backlit for 3 seconds LCD screen will display ErC if there is EEPROM data reading error or the calibrating process is not finished Please contact your supplier 3 short ticks and green backlit for 3 seconds Low voltage signal when the battery voltage is below2 61V 2 Please replace battery None Power Off Mode The thermometer will power of...

Page 16: ...anty period has not expired contact the manufacturer Battery symbol displayed when thermometer powers on The battery level is low Use new batteries of the same model or specifications Er1 is displayed The ambient temperature is lower than 10 0 C 50 0 F or higher than 40 0 C 104 0 F Take a measurement under an ambient temperature between 10 0 C 50 0 F and 40 0 C 104 0 F The temperature reading is l...

Page 17: ...gher than the typical body temperature range in the absence of a fever The thermometer probe is faulty Contact Innovo Medical 10 Technical Specifications Items Standards Model Dual mode infrared thermometer INV EF100 Applicable regulations and laws ASTM 1965 EN12470 5 GB T 19146 2010 Temperature units F C adjustable Displayed temperature range Forehead temperature mode 32 0 F 212 0 F 0 0 C 100 0 C...

Page 18: ...erature is below the minimum measurement range LCD displays H if the measured temperature is above the maximum measurement range LCD displays Er1 if the temperature measurement circuit is abnormal faulty sensor or temperature measurement circuit or the ambient temperature exceeds 50 0 F 104 0 F 10 0 C 40 0 C LCD displays ErC if the calibration process is not completed or EEPROM data recording is a...

Page 19: ... 0 6 F 0 3 C for 95 Error Bookmark not defined Error Bookmark not defined Among which T1 and T2 represent temperature value for thermometer under test respectively Tref represents the constant reference temperature This infrared thermometer meets requirements established in ASTM Standard E 1965 98 Full responsibility for the conformance of this product to the standard is assumed by Innovo Medical ...

Page 20: ...roper use are not covered under warranty 12 Symbols Symbol Description The product is a Type BF device Attention Please refer to this User Guide The action expressed in words beside the symbol is prohibited Manufacturer information including its name and address Waste electrical materials should be sent to dedicated collection points for recycling Warning A personal injury or meter damage may resu...

Page 21: ...17 Manufactured for Innovo Medical 406 Sterling Street Building 2 Camphill PA 17011 Phone 1 858 888 9781 cs innovogroups com www innovo medical com ...