background image

U Quick Start Guide 

<< Back to Contents

 

 

Copyright © Innovative Technology Ltd 2018

   

Doc: ICU Quick Start Guide 

 

 

Version: 1.2 

 

 

Page 2 of 17

 

 

1

 

DOCUMENT INTRODUCTION 

1.1

 

Related Documents 

This document should be read together with the following: 

For SSP/eSSP: 

Protocol Manual 

 SSP (GA138): SSP Interface Protocol Specification for integration

 

SSP Implementation Guide (GA973): Information for programmers and integrators

 

 

1.2

 

Manual Amendments 

Rev.  Date 

Amendment Details 

Issued 

by 

1.0 

27/04/2018  First Issue 

CW 

1.1 

18/05/2018 

Removed API information, updated to standard SSP comms 

Include new images 

 measurement diagrams etc 

Added integration sections 

CW 

1.2 

06/06/2018 

Updated SSP Comms information and UVC Section 

Added Installation and Use Section 

Changed some wording to further clarify information 

CW 

 

1.3

 

Copyright 

This  manual  set  is  Copyright  ©  Innovative  Technology  Ltd.  2018.  No  part  of  this 
publication  may  be  reproduced  in  any  form  or  by  any  means  used  to  make  any 
derivative such as translation, transformation, or adaptation without permission from 
Innovative Technology Ltd. The contents of this manual set may be subject to change 
without prior notice. 
 

1.4

 

Limited Warranty 

Innovative Technology Ltd warrants each of its hardware products to be free from 
defects  in  workmanship  and  materials  under  normal  use  and  service  for  a  period 
commencing on the date of purchase from Innovative Technology Ltd or its Authorized 
Reseller, and extending for the length of time  stipulated by Innovative Technology 
Ltd. 
A list of Innovative Technology Ltd offices can be found in every section of this manual 
set. If the product proves defective within the applicable warranty period, Innovative 
Technology  Ltd  will  repair  or  replace  the  product.  Innovative  Technology  Ltd  shall 
have the sole discretion whether to repair or replace, and any replacement product 
supplied may be new or reconditioned.  

Summary of Contents for ICU

Page 1: ...Doc ICU Quick Start Guide Version 1 2 ...

Page 2: ...5 PRODUCT SAFETY INFORMATION 3 1 6 DISCLAIMER 3 2 GET TO KNOW YOUR ICU DEVICE 6 2 1 FRONT VIEW 6 2 2 REAR VIEW 7 2 3 BOTTOM VIEW 7 2 4 DEVICE STATUS LIGHTS 8 2 4 1 Boot Up Sequence 8 2 4 2 Age Verification Sequence 8 3 MACHINE INTEGRATION 9 3 1 POWER SPECIFICATION 9 3 2 CONNECTION SPECIFICATION 9 3 3 SCREW SPECIFICATION 9 3 4 BEZEL MOUNTING 9 4 INSTALLATION AND USE 11 5 SOFTWARE INTEGRATION 12 5 1...

Page 3: ...vative Technology Ltd 2018 No part of this publication may be reproduced in any form or by any means used to make any derivative such as translation transformation or adaptation without permission from Innovative Technology Ltd The contents of this manual set may be subject to change without prior notice 1 4 Limited Warranty Innovative Technology Ltd warrants each of its hardware products to be fr...

Page 4: ...ailure or interruption of an Innovative Technology Ltd product however caused 1 5 Product Safety Information Throughout this user manual we may draw your attention to key safety points that you should be aware of when using or maintaining the product These safety points will be highlighted in a box like this Caution This is an example text This user manual and the information it contains is only a...

Page 5: ...s sind gefordert Mechanisch Feuer Aviso de seguridad Asegúrese de que la alimentación está desconectada y de que toda la energía estática es descargada antes de manipular este producto Conecte a tierra la chapa base de la manera que se indica en el manual Solo para uso con dispositivos con los cuales la compatibilidad ha sido certificada por UL LLC Tras su instalación en producto acabado tener en ...

Page 6: ...U Quick Start Guide Back to Contents Copyright Innovative Technology Ltd 2018 Doc ICU Quick Start Guide Version 1 2 Page 5 of 17 Notice IR Emitting Device This device emits IR ...

Page 7: ...ed for face depth estimation 2 Visible Camera Camera used for face age estimation and face recognition 3 Status LEDs Lights to show the status of the ICU see Section 2 4 for more information 4 ICU Logo Flashes during use to show communication with host machine 5 Visible Camera Camera used for face depth estimation 6 IR LEDs Infra red LEDs for target illumination The Focal Length of the Cameras is ...

Page 8: ...ly cable See Section 6 1 2 3 Heatsink Heatsink to allow the unit to cool itself 4 Bezel Screws The screws holding the face to the front of the unit Unscrew these to remove the face for machine mounting See Section 3 4 2 3 Bottom View Feature Description 1 Machine Screw Mounts Mounting point for machine screws Optional 2 SD Card Slot Slot for micro SD card Used for future expansion data port 3 Came...

Page 9: ...on Initialised Boot Up Completed After the boot up sequence is completed the green LED on the ICU device will remain illuminated When communications are received from the host machine the ICU logo will begin to flash to indicate receipt and response The boot up sequence typically takes around 1minute to complete 2 4 2 Age Verification Sequence After receipt of an enable command see Section 5 1 the...

Page 10: ...e is a standard USB Type A to Type B Micro USB cable This micro USB cable provides the physical link through which communications and video are transmitted The maximum length of this data cable is 3 metres 3 3 Screw Specification The table below shows the screw specifications for the different screws on the ICU device The bezel screws are provided with the unit as it is already attached the other ...

Page 11: ... Guide Version 1 2 Page 10 of 17 Ensure that the cut out area of the host machine is large enough so as not to cover the cameras See Section 6 1 1 for measurement drawings The minimum and maximum widths of the machine panel is shown in the diagram below measurements in millimetres ICU Device Bezel ...

Page 12: ...tomated exposure settings that help to reduce poor illumination conditions However despite this the location of the ICU and the surrounding lighting is key to achieving the best accuracy Consider the points below when deciding on the location of the installation Do Locate ICU device 60 80 cm from the subject s face Place the ICU device so that the subject will look into the camera Ensure the subje...

Page 13: ...o a PC standard COM Port and UVC drivers will be enumerated These are then used for interfacing with your application The flow chart below shows the basic command sequence when communicating via SSP See SSP manual and the SSP Implementation guide for more information Ensures the communication packets are synchronized from this point Ensures the correct version of SSP is being used Request informat...

Page 14: ...nitialising Please wait until this is no longer reported before attempting to enable or modify the ICU Face Detected 0x14 Face detected in central camera s field of view Age Detected 0x15 Depending on ICU settings Age Verify or Age Estimate this will report either a Pass Check or the estimated age See SSP Manual for further explanation of the data bytes Error Event 0x16 An error occurred Details a...

Page 15: ...2 UVC Webcam USB Video Class UVC is a defined standard for USB video devices To simplify development the ICU falls into this family of devices The following indicates a typical UVC application interaction within an operating system OS More information on the USB Video Class can be found here www usb org developers docs devclass_docs ...

Page 16: ...U Quick Start Guide Back to Contents Copyright Innovative Technology Ltd 2018 Doc ICU Quick Start Guide Version 1 2 Page 15 of 17 6 APPENDIX 6 1 2D Drawings 6 1 1 ICU Device ...

Page 17: ...U Quick Start Guide Back to Contents Copyright Innovative Technology Ltd 2018 Doc ICU Quick Start Guide Version 1 2 Page 16 of 17 6 1 2 Power Cable ...

Page 18: ...sed in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or mo...

Reviews: