![Innovative Cleaning Equipment SP-2SL User Manual Download Page 2](http://html1.mh-extra.com/html/innovative-cleaning-equipment/sp-2sl/sp-2sl_user-manual_2063856002.webp)
Page 2 of 4 | 04282014
User Manual: 2 Gallon Pump-Up Spray Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
REQUIREMENTS
Liquid temperature
range
40-100˚F (4.4-37˚C)
Chemical
compatibility
Chemical products used with this
equipment must be formulated
for this type of application and
compatible with unit materials and
pump seals. For more information
on chemical compatibility, consult
the manufacturer or MSDS for your
product or contact our customer
service department.
SPECIFICATIONS
Power type
Manual
Chemical pickup type Draws from pre-mixed solution
Number of products
unit can draw from
One product
Capacity
2 gallons (7.6 liters)
Discharge hose
diameter/length
4 ft. (1.2 m) hose with 3/8 in. (9.5 mm)
inside diameter
Discharge wand/tip
type
Polypropylene trigger handle with 40˚
fan tip
Pump seals
Viton
Read this manual completely and understand the
machine before operating or servicing it.
•
Always wear appropriate personal protective equipment
(PPE) when operating or servicing unit.
•
Always follow all chemical safety precautions and
handling instructions provided by the chemical
manufacturer and Material Safety Data Sheet (MSDS).
•
If this unit is modified or serviced with parts not listed in
this manual, the unit may not operate correctly.
•
Never point the discharge wand at yourself, another
person, or any object you do not want covered in
chemical.
•
Always depressurize unit after use (as described in the
After Use Instructions). Always store unit depressurized.
•
Never leave unit unattended while pressurized.
•
Always depressurize unit before attempting to remove
the pump assembly.
•
Do not pressurize unit by any means other than the built-
in pump assembly.
•
Do not modify or remove pressure relief valve. Do not
use unit if pressure relief valve is not operational.
•
Always carry unit by the handle in locked position.
•
Do not exceed a fluid temperature of 100˚F (37˚C).
•
Never use unit with hydrocarbons or flammable
products.
WARNING
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine
components, and hazardous fluids in an environmentally safe
way according to local waste disposal regulations.
Always remember to recycle.
*Specifications and parts are subject to change without notice.