INSTALLATION

  The maximum length of the holes is of 1 m and there 

must  be  no  bends.  Use  the  supplied  grids  or  grids 
with the same characteristics.

For the unit to work, two holes must be placed as indicated 
on the template;

The  holes  on  the  wall  must  be  drilled  using  suitable 
equipment  that  facilitates  your  work  and  that  does  not 
cause damage or excessive inconvenience to Your client. 
The best tools to make big holes on walls are special drills 
(called "core drills") with a high torque and whose speed 
can be adjusted according to the diameter of the hole to 
make and to the material. In order to avoid excessive dust 
and debris in the room, "core drills" can be combined with 
suction  systems  composed  of  a  vacuum  connected  to 
e.g. a suction cup placed next to the perforation tip.
In order to make the holes, proceed as follows:

Place the template provided against the wall respecting 
the  minimum  distances  from  the  ceiling,  the  floor 
and the side walls as indicated on the template. The 
template can be held in place using adhesive tape.

Mark  the  centre  of  each  hole  with  a  small  drill  or  a 
punch before actual drilling.

Using the core drill, make two holes for inlet and outlet 
air. 

  The holes must be drilled slightly downwards to avoid 

water from entering. 

The majority of the removed material is expelled outwards, 
so please be careful that it doesn't hit people or objects. In 
order to avoid breaking the outer plaster, be careful while 
drilling the final part of the hole and ease the pressure on 
the core drill. 
Drill  the  6  holes  for  the  bracket  as  indicated  on  the 
template. 
The appliance weights more on the right, so make sure to 
secure it properly on this side. The holes must have an 8 
mm diameter to accommodate the 6 supplied plugs. 
In any case, check the characteristics and the consistency 
of the wall to see whether specific plugs are needed. 

  The  manufacturer  cannot  be  held  responsible  for 

any  underestimates  of  the  structural  consistency  of 
the anchoring arranged by the installer. We therefore 
encourage  you  to  pay  the  utmost  attention  to  this 
operation  as,  if  performed  badly,  it  could  cause 
serious damage to people and objects.

Drill  a  hole  in  the  position  indicated  on  the  template  for 
those  heat-pump  appliances  without  a  condensation 
drain  built  in  the  wall  in  order  to  enable  the  draining  of  
condensation. 

Holes for M8 plugs

Electrical connection area

ø

160 mm Holes for air channelling

ø

14 mm Condensation drain

Assembling the unit 

Summary of Contents for 2.0

Page 1: ...something new in the air Manuale d installazione Installation manual ehpocaGEO something new in the air Installation manual 2 0 ...

Page 2: ... electronic equipment 2011 65 EC RoHS2 Waste electrical and electronic equipment 2002 96 EC WEEE Energy consumption indication on the labels of energy related products 2010 30 EU Pictograms in the next chapter provide the necessary information for a correct and safe use of the machine in a rapid unmistakable way Symbols U User Refers to pages containing instructions or information for the user I I...

Page 3: ...parts Installation Installation mode Choosing the position of the unit Assembling the unit Assembling air ducts and external shutters Mounting the appliance on the bracket Electrical connection High low installation configuration Setting cool only or heat only modes Touch screen display key lock Operations tests and anomaly diagnosis Troubleshooting Periodic Maintenance Troubleshooting Technical d...

Page 4: ...er is transferred to another owner or user or transferred to another system If it gets damaged or lost please request another copy to the local INNOVA Technical Assistance Service Any repair or maintenance operations must be performed by the Technical Assistance Service or by qualified personnel in accordance with this booklet Do not modify or tamper with the appliance as this could lead to danger...

Page 5: ...ating mode by simply touching the screen The unit then works in cool only mode without the need to use the condensation drain pipe The orientation of the air flaps can also be adjusted by simply pressing one key Receipt and unpacking The packing is made of suitable material and carried out by expert personnel All units are checked and tested and are delivered complete and in perfect conditions how...

Page 6: ... Supplied components The supply comprises of the parts listed in the following table Before assembly please check that they are all at hand External grids for air inlet and outlet with springs 2 pcs Chains 4 pcs Screws and plugs kit 6 pcs Bracket for wall mounting Use and maintenance booklet Remote control Paper template for holes CR2025 3V remote control battery Wall inlet pipes 2 pcs Energy effi...

Page 7: ... 12 1 10 11 EN GENERAL Unit parts Air outlet flaps Touch screen display Front panel Outdoor air suction Outdoor air outlet Air suction grid Air filters Outdoor air outlet fan Outdoor air heat exchanger Compressor Indoor air heat exchanger Electronic board ...

Page 8: ...ollowing requisites Respect the minimum distances indicated in the picture The wall on which you wish to anchor the unit must be robust and able to support its weight Leave enough space around the unit to perform maintenance operations Nothing must obstruct the air flow both in the top suction part curtains plants furniture and in the lower outlet part as it could cause vibrations which might prev...

Page 9: ...th a small drill or a punch before actual drilling Using the core drill make two holes for inlet and outlet air The holes must be drilled slightly downwards to avoid water from entering The majority of the removed material is expelled outwards so please be careful that it doesn t hit people or objects In order to avoid breaking the outer plaster be careful while drilling the final part of the hole...

Page 10: ...t is necessary to perform a siphoning operation before inserting the pipe in the main drainage Said siphon must be placed at least 300 mm under the mouth of the appliance If the line flows into a container e g a tank do not close the container hermetically and avoid immersing the draining pipe into the water The hole for the condensation pipe must always lean towards the outside The exact position...

Page 11: ...ensioning the springs use a bolt cutter to remove any excess chain anchor the hook of the chain to wall B Use only the supplied grids or grids with the same characteristics After checking that the bracket is anchored to the wall and that all necessary electrical connections and condensation drain predispositions have been made you can mount the conditioner Lift it by the sides of the bottom base u...

Page 12: ...against overloads and or short circuits using a 10 at delay fuse or other equivalent devices is recommended This operation must be performed only by the installer or by authorised personnel in compliance with current national regulations It is essential to disconnect the main switch before making any connection or maintenance operation in order to avoid any risk of electrocution To carry out direc...

Page 13: ...ole After adjusting the air outlet flap position it is necessary to set up the electronic control of the appliance Keep pressed the button on the display for 5 seconds The dn lower wall symbol lights up on the display Press the button again The uP upper wall symbol lights up on the display If no other operations are performed in the following 2 seconds the new setting is memorised For the applianc...

Page 14: ...m appears on the display The key lock is activated by keeping the Timer symbol on the touch screen display pressed for t h r e e seconds Any action is prevented by the user The stand by symbol flashes at 1 second intervals To deactivate the lock keep the Timer symbol pressed for three seconds once again Any key on the remote control deactivates the lock Open CP contact Touch screen display key loc...

Page 15: ...ntration of impurities in the air or when you wish to start up the appliance after a period of inactivity The filter is placed on the top part of the appliance To extract the filters open the grid and remove it extract the filters by lifting them remove the dust from the filter with a vacuum cleaner or washing it in running water without using detergents or solvents and leave to dry put the filter...

Page 16: ...heat Try to reduce the thermal refrigeration load of the room with the following advice Cover large windows exposed to sunlight with curtains or with external maskings blinds porches reflecting films etc The room must remain closed for as long as possible Avoid turning on halogen lamps or other high energy consumption appliances such as small ovens steam irons cooking plates etc Alarm displayed Ca...

Page 17: ...refrigerant gas Casing protection level Max working pressure Noise pressure measured 1 m away and 1 5 m high Relevant regulation EN 14511 1 2 3 4 Operating limits Technical data Cooling power 1 Heating power 2 Power absorbed when cooling 1 Power absorbed when heating 2 Annual energy consumption for cooling 1 Dehumidification capacity Power supply voltage EER COP Energy efficiency ratio when coolin...

Page 18: ...18 S I U EN NOTES ...

Page 19: ...19 S I U EN NOTES ...

Page 20: ... 0465 670104 fax 39 0465 674965 info innovaenergie com realised with iés technology by N273027A Rev 0 INNOVA s r l Fraz Strada 16 38085 PIEVE DI BONO TN ITALY tel 39 0465 670104 fax 39 0465 674965 info innovaenergie com realised with iés technology by N273027A Rev 0 ...

Reviews: