STEP 4: Connect the TargetViewer to the sensor 

 

Press the connect-button in the top left corner 

 

 

 

Choose the correct COM Port and click OK 

 

 

 

 

STEP 5: Observe moving detections 

 

Detections are output in a target list via UART 

 

Detailed information about a target is displayed in the target list in the lower area of the software 

- Red indicates targets moving toward the sensor 

- Green indicates targets moving away from the sensor 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The environment is set up properly and ready for operation. 

The sensor provides further filter settings. If you want to take advantage of them progress with the next steps. 

Summary of Contents for IMD-3101

Page 1: ...IMD3101_V1 xxx exe and follow the instructions of the installation on your Windows PC STEP 2 Mount the IMD 3101 sensor in a stationary position e g on a tripod Align the sensor in one direction Check...

Page 2: ...o the sensor Press the connect button in the top left corner Choose the correct COM Port and click OK STEP 5 Observe moving detections Detections are output in a target list via UART Detailed informat...

Page 3: ...hould be applied Therefore you have three options v_both Standard Choose v_both and both parameters v_neg and v_pos will be traced E g if you set the velocity filter 2m s to 5m s the negative 2m s to...

Page 4: ...detection of targets with different velocities E g Detection of targes in Alarm Zone 1 with a velocity between 2 m s up to 4 m s and in Alarm Zone 2 between 4 m s up to7 8 m s Together with the direc...

Page 5: ...ge 5 QUICK START GUIDE IMD 2000 STEP 7 Write settings to sensor After you set the configuration send the configuration to the sensor If the configuration has been sent successsfully the following mess...

Page 6: ...property of InnoSenT GmbH and shall not be disclosed by the recipient to third parties without prior consent of InnoSenT in writing Page 6 QUICK START GUIDE IMD 2000 STEP 9 Evaluate the sensor Choose...

Page 7: ...clusive property of InnoSenT GmbH and shall not be disclosed by the recipient to third parties without prior consent of InnoSenT in writing Page 7 QUICK START GUIDE IMD 2000 InnoSenT GmbH Am Roedertor...

Reviews: