STEP 1: Install the IMD-3101 Target Viewer 

 

The software package can be downloaded from our website at  

https://www.innosent.de/en/downloadportal/

 

 

Open the setup file of the IMD-3101 Target Viewer software package:  
IMD-3101 -> GUI -> TargetViewer - IMD3101_V1.xxx.exe and follow the instructions of the installation on your 
Windows PC. 

 

STEP 2: Mount the IMD-3101 sensor in a stationary position, e.g. on a tripod 

 

Align the sensor in one direction. 

 

Check the correct orientation and mounting angle of the sensor for your required Field of 
View (FOV).  

 

STEP 3: Connect the module to your PC 

 

To connect the sensor to your PC via USB-port, use a TTL-232R-3V3 cable from FTDI. The 
connector is compatible with the UART-USB-Converter. The cable is not included in the 

evaluation kit

.

 

 

The orientation must be according to this picture. 
You can find information about the sensor’s pinout in its data sheet.

 

 

 

 

Configure cable latency in Windows device manager to 1ms. Pay attention to the COM-Connection-Port 
you placed the sensor. 
 

Summary of Contents for IMD-3101

Page 1: ...IMD3101_V1 xxx exe and follow the instructions of the installation on your Windows PC STEP 2 Mount the IMD 3101 sensor in a stationary position e g on a tripod Align the sensor in one direction Check...

Page 2: ...o the sensor Press the connect button in the top left corner Choose the correct COM Port and click OK STEP 5 Observe moving detections Detections are output in a target list via UART Detailed informat...

Page 3: ...hould be applied Therefore you have three options v_both Standard Choose v_both and both parameters v_neg and v_pos will be traced E g if you set the velocity filter 2m s to 5m s the negative 2m s to...

Page 4: ...detection of targets with different velocities E g Detection of targes in Alarm Zone 1 with a velocity between 2 m s up to 4 m s and in Alarm Zone 2 between 4 m s up to7 8 m s Together with the direc...

Page 5: ...ge 5 QUICK START GUIDE IMD 2000 STEP 7 Write settings to sensor After you set the configuration send the configuration to the sensor If the configuration has been sent successsfully the following mess...

Page 6: ...property of InnoSenT GmbH and shall not be disclosed by the recipient to third parties without prior consent of InnoSenT in writing Page 6 QUICK START GUIDE IMD 2000 STEP 9 Evaluate the sensor Choose...

Page 7: ...clusive property of InnoSenT GmbH and shall not be disclosed by the recipient to third parties without prior consent of InnoSenT in writing Page 7 QUICK START GUIDE IMD 2000 InnoSenT GmbH Am Roedertor...

Reviews: