![Innoquest SpotOn FM-15 Product Manual Download Page 2](http://html1.mh-extra.com/html/innoquest/spoton-fm-15/spoton-fm-15_product-manual_2062935002.webp)
2
1.0 Introduction
1.1 Meter Diagram
1.2 Features
•
Measures up to 15 GPM (58 Liters/min)
•
Test for worn/plugged nozzles as well as regulator problems
•
Simple waterproof design has no moving parts
•
Digital readings in either GPM, Liter/min, or Liter/hr
•
Just place under flow until reading is displayed
•
Patented Design US # 8,297,131
LCD Display
Diffuser Pad
START Button
Battery Cover
3
2.0 Specifications
Measurement Range:
.08-15.0 GPM, .30-58 L/min, 20-3480 L/hr
(Gallons are US Gallons)
Accuracy:
Greater of +/- 4% or one digit (Meter must be held steady
during fill for best accuracy)
Resolution:
0.01 GPM (.08 – 9.99 GPM) or 0.1 GPM (10.0 – 15.0 GPM)
0.01 L/min (0.30 – 9.99 L/min) or 0.1 L/min (10.0 – 58.0 L/min)
10 L/hr (20 L/hr – 3480 L/hr)
Battery:
Two (2) “N” size alkaline batteries (included)
Battery Life
: 2 years, meter has low battery indicator
Size:
8.0 in (20.3cm) tall by 8.0 in (20.3 cm) diameter
Weight:
1.2 lbs (545 g) weight
Construction:
Break resistant plastic & Stainless Steel
Environmental:
35-120°F (2-49°C) / up to 100% RH temporary use with
a period to allow meter to dry out. Do not use meter then place
in air tight container while still wet.
Fluid Compatibility:
Water and water based solutions only
Country of Origin:
Made in USA