7.0 Warranty & Service

 

 
 
 

One Year Warranty 

 

Innoquest, Inc. warrants this product to be free from defects in 
materials and workmanship under normal use and service for a period 
of one (1) year from date of purchase.  This warranty extends only to 
the original purchaser and shall not apply to any product which, in 
Innoquest’s sole opinion, has been subject to misuse, alteration, 
abuse, or abnormal conditions of operation or handling.  Innoquest’s 
obligation under this warranty is limited to repair or replacement of the 
product which is returned to Innoquest.  Innoquest accepts no liability 
for whatever damages may be caused by a malfunctioning product. 

 

Repair & Service Policy

   

 

Product returned to Innoquest for repair or service must follow the 
guidelines set forth as follows:  Return of the product for warranty or 
service repair will be the responsibility of the purchaser (Innoquest 
does not pay inbound shipping charges).  All returns must receive an 
RMA number by calling Innoquest prior to return of the product.  The 
RMA number must be clearly marked on the outside of the shipping 
carton.  If the customer is returning product for non-warranty related 
repair or service, a minimum charge will apply for accessing the 
product’s repair needs and further work will not be completed without 
the customer’s approval. 
 

 

 

 

 

Record Your Serial Number 

 
 

Model # _______________ 

 

 

 

 

 

 

 

Serial #  _______________ 

 

 

910 Hobe Road  

 

 

 

Woodstock, IL 60098 

 

 

 

Toll Free: 800-637-1623 
Phone: 815-337-8555 
Fax: 815-337-8556 

[email protected]

 

www.innoquestinc.com   

 

                © 2017 Innoquest, Inc. USA  P/N 32480 Rev. 0 (Revised 2/22/17) 

Summary of Contents for SpotOn 29360

Page 1: ...Product Manual Innoquest Item 29360 Digital Soil Compaction Meter ...

Page 2: ...atures 3 4 0 Specifications 3 5 0 General Operation 4 5 1 Installing the Batteries 4 5 2 Zero Calibration 4 5 3 Changing Display Units 5 5 4 Taking a Reading 5 5 5 Probe Tip Cover 6 5 6 Probe Tip Replacement 6 6 0 Troubleshooting Maintenance 6 7 0 Warranty Service 7 ...

Page 3: ... sharp metal tip could cause damage to packaging containers or personal Always use the included tip cover when transporting the meter See section 5 5 for more info 2 0 Meter Diagram Stainless Steel Shaft with Depth Marks Splash Dust Proof Digital Display Extra Hard Tool Steel Tip Replaceable Battery Compartment In Handle Power Button Zero Button Color Coded Bar Graph Display ...

Page 4: ...ft with depth marking every 4in 10cm Ultra hard tool steel cone for years of service Made in USA 4 0 Specifications Usable Probe length 30in 76cm Range 0 to 825 PSI 0 to 5690 kPa Resolution 1 PSI 7 kPa Accuracy 15 PSI 100 kPa Waterproof IP64 rating Dust Tight Splash Resistant Meter Size 35in 89cm x 11in 28cm x 3in 7 6cm Shipping Box Size 37in 94cm x 13in 33cm x 5in 13cm Battery Two 2 AA LR6 Size A...

Page 5: ...Press the ZERO button and continue holding the meter steady and above the ground until the zero function completes and the LCD displays a 0 value The compaction meter should show a zero value when suspended in air prior to taking a probing with the meter Temperature changes battery voltage changes and rough handling can cause shifts in the meter s zero point All the above variations are easily and...

Page 6: ...sult of side loading on the shaft Penetration Rate ASABE Engineering Practice EP542 recommends a Penetration Rate of 1 2 in second 30mm sec for best accuracy Maximum Reading Display The maximum compaction reading attained during the penetration will automatically display as the probe is withdrawn from the soil The display will show HI followed by the maximum compaction reading This reading will sh...

Page 7: ...ttached with removable type thread locker so some force may be required to loosen it The probe tip should be replaced when the diameter of the cone s base measures less than 0 490in 12 45mm diameter 6 0 Troubleshooting Maintenance Errors If an error message Err2 or Err3 is displayed during the zero process then retry the zero button and assure the meter s shaft and tip are hanging vertically below...

Page 8: ...ed to Innoquest for repair or service must follow the guidelines set forth as follows Return of the product for warranty or service repair will be the responsibility of the purchaser Innoquest does not pay inbound shipping charges All returns must receive an RMA number by calling Innoquest prior to return of the product The RMA number must be clearly marked on the outside of the shipping carton If...