The installation is completed when the test has been passed.
The Heat Sensor will then give an alarm. This user manual, accessories
and stickers should be left with the product for future reference.
Return the power
Switch on the power at the
consumer unit.
Perform function test
Wait 30 seconds after switching
on the power. Press and hold
the button until the Heat Sensor
emits a “beep” ( ) and the red
LED flashes. Release the hold.
The Control Unit will switch off
the cooker and give an alarm
signal every 5 seconds. The Heat
Sensor will also emit a test alarm
after a few seconds.
Note!
Check that there is no
power going to the cooker.
Reset the alarm
It is important to reset the alarm
after a function test to ensure
power to the cooker. Reset the
test alarm by pressing the button
once.
Check that the cooker can be
turned on (or that there is
voltage in the Control Unit).
If the Heat Sensor does not
respond or if the test alarm
cannot be reset, see page 20,
points 5 and 6.
FUNCTION TEST
1
2
3
Installation is now ready.
When connecting the Stove Guard for the first time it is advisable to wait 15 minutes before normal
cooker use to allow the Stove Guard to perform final system checks.