background image

1. Installation and testing

STOVE GUARD SGK

430

 

INSTALLATION  MANUAL

Compatibility:

 All electric ranges. Max. hob width 36'' (90 cm).

Additional installation parts required:

  

-  Wall installation: 

Mounting bracket, part no. SAI500-ABX

  For indoor use only. 
  Not suitable for use in professional kitchens. 
  Disconnect power before installation.
  Ensure correct location. Carry out test alarm.

STEP 1 - 

Install the Intelligent Heat Sensor

Install the Intelligent Heat Sensor underneath the range hood or on the wall.

Range hood installation

•   See tables above for your required installation zone. Zone 1 (see image 

1): above the central point of the burners (max. 6'' (15 cm) tolerance to 

the side). Zone 2: see image 1. 

•   At minimum 4'' (10 cm) distance from range hood lights – 2'' (5 cm) for 

LED lights.

•   On a horizontal surface so that it is pointing directly downwards.

   

is clean (from dirt and grease) by using a detergent. Dry well prior to attaching 
the Sensor.

1.

the protective backing from the Sensor mounting plate and stick the Sensor to 

the underside of the range hood. Ensure that the LED on the side of the Sensor 

points towards you (see image 2, A). Remove the Sensor from the plate (Sensor 

2.

 Remove the red battery disconnection piece from the Sensor (see image 

2, B), save for possible later use. Put the Sensor back on the mounting plate, 

ensure that it goes the right way round, and fits tightly on the plate so that
there are no gaps.

3.

 Measure the distance between the range top and the range hood. For 

standard distances between 18'' and 24'' (45 cm - 60 cm), no sensitivity level 

adjustment is necessary. For all other distances set the Heat Sensor sensitivity 

manually, see instructions on the reverse of this sheet.

Image 1

Image 2

Battery 

disconnection 

piece

Zone 1: above the central point of the cooker (max. 6” tolerance to the side).

6” (15cm)

B

A

Hob width 24'' (60 cm)

 - Heat Sensor installation options

Options  

(height measured from range top)

Location

Range hood  

(horizontal hoods only)  

18'' – 32'' (45 – 80 cm)

Zone 1 (see image 1). 

Range hood  

(horizontal hoods only)  

32'' – 40'' (80 - 100 cm)

Zones 1 and 2  

(see image 1). 

Wall  

26 - 32'' (65 - 80 cm)

Mounting bracket required  

(purchased separately). 

Hob width 36'' (90 cm)

 - Heat Sensor installation options

Options  

(height measured from range top)

Location

Range hood  

(horizontal hoods only) 

 

32'' – 40'' (80 - 100 cm)

Zone 1 (see image 1).

Wall  

28 - 32'' (70 - 80 cm)

Mounting bracket required  

(purchased separately). 

STEP 2 - 

Install the Control Unit

Disconnect power. Connect  the Control Unit between the range and the 

power outlet 

STEP 3 - 

Test the Stove Guard

1.

 Reconnect power. Wait for that control unit emits a ringing sound or approx.   

30 seconds, then press the Sensor cover until the Sensor emits a beep. 

2.

 Check that the Control Unit emits ringing sound. After a moment, the Heat 

Sensor emits an alarm signal. Check that the cooker has no power, then return 

power by pressing the Sensor cover once. 

3.

 Check that the range turns on. 

If the Heat Sensor does not respond, see troubleshooting, below.

 

The installation is now ready. 

Instructions for wall installations are found in the mounting  

bracket manual.

The Sensor can be attached also to the grease filter grid. Ensure that the surface

Allow the Intelligent Heat Sensor to first adjust to room temperature. Remove

will emit a beep). Press the  mounting plate firmly towards the surface to ensure 
a secure fit.

Reviews: