![Innogy 10267413 Manual Download Page 4](http://html1.mh-extra.com/html/innogy/10267413/10267413_manual_2062575004.webp)
4
Function
The pluggable switch switches itself on
and off individually, as controlled by the
user, in response to the radio commands it
receives. The radio commands for the plug-
gable switch are issued by pressing but-
tons, by remote control, via the SmartH-
ome user interface or
programme-controlled via the SmartHome
central unit.
Hazard warning
• Pluggable switches must not be plugged
into each other.
• Do not open the pluggable switch. It
does not contain any parts to be ser-
viced by the user. If a fault occurs, please
contact our SmartHome service. Only
operate the device indoors. Avoid the
influence of humidity, dust, sunlight and
other heat radiation.
• Do not push the pluggable switch
beyond the specified performance limit.
• Overloading can destroy the device or
cause a fire or an electrical accident.
• Do not connect any end devices to the
pluggable switch which could cause fires
or other damage if they are switched on
while unsupervised (e.g. irons).
• Only use the pluggable switch in perma-
nently installed sockets with grounding
contacts. Do not use it in multiple socket
outlets or with extension leads.
• Always unplug the end device from the
pluggable switch before carrying out
any work on the end device (e.g. chang-
ing the bulb).
Commissioning
After it has been plugged into the easily
accessible socket, the pluggable switch
will try for three minutes to automatically
integrate itself (LED flashes briefly every
ten seconds). Integrate the device via the
user software in the SmartHome system.
When the device has been successfully
integrated, the LED lights up for approxi-
mately two seconds.
General information
eQ-3 Entwicklung GmbH hereby declares
that this device meets the basic require-
ments and the other relevant regulations
laid down in Directive 1999/5/EC.
You can find the complete declaration of
conformity at:
www.eq-3.de/service/downloads.html
eQ-3 Entwicklung GmbH,
Maiburger Str. 36, D-26789 Leer
Technical data
Name of device
PSS
Supply voltage
230V/50Hz
Standby consump-
tion
0.5W
Radio frequency
868.3MHz
Max. transmission
power
10mW
Receiver class
SRD Class 2
Type of switch
Separately assem-
led switch
Max. switching
power
3680W
Breaking capacity
16A (ohmic load)
Impulse withstand
voltage
2500V
Relay
NO contact
Operating mode
S1
Protection class
IP20
Ambient tempera-
ture
+5°C to +35°C
Dimensions
60x130x77mm
(WxHxD)
Weight
180g
Technical changes reserved.