1.8”  SATA  SSD  3SR-P 

9     

                      Rev. 1.3                                                                      TPS, March 2017 

2. Product Specifications 

2.1 Capacity and Device Parameters 

1.8” SATA SSD 3SR-P device parameters are shown in Table 1. 

Table 1: Device parameters 

Capacity 

LBA 

Cylinders  Heads  Sectors 

User 

Capacity(MB) 

8GB 

13695696

 

13587 

16 

63 

6687 

16GB 

29323728 

16383 

16 

63 

14318 

32GB 

60579792 

16383 

16 

63 

29580 

64GB 

121138416 

16383 

16 

63 

59150 

128GB 

242255664 

16383 

16 

63 

118289 

256GB 

484490160 

16383 

16 

63 

236568 

2.2 Performance 

Burst Transfer Rate:    6.0Gbps 

Table 2: Performance 

Capacity 

8GB 

16GB 

32GB 

64GB 

128GB 

256G5B 

Sequential 

Read (max.) 

400MB/sec 

400 MB/sec 

460MB/sec 

460 MB/sec 

475 MB/sec 

490 MB/sec 

Sequential 

Write (max.) 

110 MB/sec 

130 MB/sec  240 MB/sec  330 MB/sec 

340 MB/sec 

340 MB/sec 

Note: Based on CrystalDiskMark 3.01 with file size 1000MB 

2.3 Electrical Specifications 

2.3.1 Power Requirement 

Table 3: Innodisk 1.8” SATA SSD 3SR-P Power Requirement 

Item 

Symbol 

Rating 

Unit 

Input Voltage 

V

IN

 

+5 DC +- 5%   

2.3.2 Power Consumption 

Table 4: Power Consumption 

Mode 

Power Consumption (mA) 

Read 

450 (max.) 

Write 

600 (max.) 

Idle 

190 (max.) 

* Target: 1.8” SATA SSD 3SR-P 256GB

   

 

Summary of Contents for 3SR-P Series

Page 1: ...3SR P Series Customer Customer Part Number Innodisk Part Number Innodisk Model Name Date Innodisk Approver Customer Approver...

Page 2: ...sumption 9 2 4 ENVIRONMENTAL SPECIFICATIONS 10 2 4 1 Temperature Ranges 10 2 4 2 Humidity 10 2 4 3 Shock and Vibration 10 2 4 4 Mean Time Between Failures MTBF 10 1 8 CE AND FCC COMPATIBILITY 11 2 6 R...

Page 3: ...ev 1 3 TPS March 2017 4 INSTALLATION REQUIREMENTS 16 4 1 1 8 SATA SSD 3SR P PIN DEFINITION 16 4 2 ELECTRICAL CONNECTIONS FOR 1 8 SATA SSD 3SR P 16 4 3 FORM FACTOR 16 4 4 DEVICE DRIVER 16 5 PART NUMBER...

Page 4: ...inary First Released Dec 2013 Rev 1 0 1 Update performance 2 Update power consumption 3 Add CE FCC certificates 4 Update TBW Apr 2014 Rev 1 1 Add specification of Quick Erase function Nov 2014 Rev 1 2...

Page 5: ...ERFORMANCE 9 TABLE 3 INNODISK 1 8 SATA SSD 3SR P POWER REQUIREMENT 9 TABLE 4 POWER CONSUMPTION 9 TABLE 5 TEMPERATURE RANGES FOR 1 8 SATA SSD 3SR P 10 TABLE 6 SHOCK VIBRATION TESTING FOR 1 8 SATA SSD 3...

Page 6: ...8 SATA SSD 3SR P 6 Rev 1 3 TPS March 2017 List of Figures FIGURE 1 INNODISK 1 8 SATA SSD 3SR P 7 FIGURE 2 INNODISK FID 1 8 SATA SSD 3SR P BLOCK DIAGRAM 14 FIGURE 3 SIGNAL SEGMENT AND POWER SEGMENT 16...

Page 7: ...8 SATA SSD 3SR P is compliant with MIL STD 810F G standards The SSD is equipped ruggedized hardware design and thus it can perform well in the harsh environment Innodisk 1 8 SATA SSD 3SR P is designe...

Page 8: ...pliant with Serial ATA Gen 1 Gen 2 and Gen 3 specification Gen 3 supports 1 5Gbps 3 0Gbps 6 0Gbps data rate The SATA connector uses a 7 pin signal segment and a 9 pin power segment 1 4 1 8 inch Form F...

Page 9: ...2 2 Performance Burst Transfer Rate 6 0Gbps Table 2 Performance Capacity 8GB 16GB 32GB 64GB 128GB 256G5B Sequential Read max 400MB sec 400 MB sec 460MB sec 460 MB sec 475 MB sec 490 MB sec Sequential...

Page 10: ...en Failures MTBF Table 7 summarizes the MTBF prediction results for various 1 8 SATA SSD 3SR P configurations The analysis was performed using a RAM Commander failure rate prediction Failure Rate The...

Page 11: ...equential Write 32GB 1728 Sequential Write 64GB 3456 Sequential Write 128GB 6912 Sequential Write 256GB 13824 Sequential Write 2 8 Transfer Mode 1 8 SATA SSD 3SR P support following transfer mode Seri...

Page 12: ...er P2 V33 3 3V Power Pre charge P3 GND P4 GND P5 V5 5V Power Pre charge P6 V5 5V Power P7 R Reserved Key Key Key P8 Optional Vendor Specific P9 QE Quick Erase Note Active low Quick Erase the SSD will...

Page 13: ...function and can be removed or connected when the system is powered on The user has to avoid hot plugging the SSD when it is configured as the boot drive with the operating system installed Surprise...

Page 14: ...Communication with the host occurs through the host interface using standard Serial ATA protocol Communication with the flash memory occurs through Innodisk s SATA III controller 3 2 SATA III Controll...

Page 15: ...that contain one or more invalid bits whose reliability are not guaranteed Bad Blocks may be present when the SSD is shipped and may also develop over the lifetime of the SSD When Bad Blocks are dete...

Page 16: ...SATA interface also has a separate connector for the power supply Please refer to the pin description on Table 8 for further details 4 3 Form Factor Please turn off your computer and open your compute...

Page 17: ...ode 1st Disk Code 13th Flash Mode D Disk S Synchronous Flash Code 2nd Feature Set Code 14th Operation Temperature R InnoRobust C Standard Grade 0 70 W Industrial Grade 40 85 Code 3rd 5th Form Factor S...

Page 18: ...1 8 SATA SSD 3SR P 18 Rev 1 3 TPS March 2017 6 Appendix...

Page 19: ...1 8 SATA SSD 3SR P 19 Rev 1 3 TPS March 2017...

Page 20: ...1 8 SATA SSD 3SR P 20 Rev 1 3 TPS March 2017...

Page 21: ...1 8 SATA SSD 3SR P 21 Rev 1 3 TPS March 2017...

Reviews: