![INNO VIEW 5 Pro User Manual Download Page 12](http://html1.mh-extra.com/html/inno/view-5-pro/view-5-pro_user-manual_2062296012.webp)
12
VIEW 5 Pro
3.3 How to Make a Splice
Put the optical fiber in
① Open the safety shield.
② Raise the fiber clamps.
③ Position the fibers into V-grooves. Make sure the fiber ends are between the V-groove edges and the electrode tip.
④ Clamp the fiber in position by lowering both sets of fiber clamps.
⑤ Close the safety shield.
⚠ Note:
Make sure to avoid sliding the fibers along V-grooves, but rather position them over
V-grooves and tilt them down into place (as shown below).
Inspecting the Fibers
Before continuing with splicing, inspect the fibers whether they are clean and well-cleaved. If any defects are found, please
remove the fibers and prepare again.
⚠ Note:
The fibers are checked automatically when you press Set button. The splicerautomatically focuses the fibers and checks
for damage or dust particles.
Splicing
① Select any appropriate splice mode.
② Start splicing by pressing “SET” button.
⚠ Note:
If the splicer is set as “Auto mode”, splicing will start automatically once the safety
shield is closed.
Fiber ends visible
on the monitor.
Fiber ends
outside monitor.
Fiber ends above
and below monitor,
not possible to find
automatically.
a.
b.
c.
Dust on fiber
Chip
Tag