35
2002 - INLINE, INC.
MSX1616 OPERATION MANUAL - v1.0 5/8/02
COMMAND
DESCRIPTION
[PCLpPmmmabcde]
[PCLpPmmm?]
Loads ASCII command string to a preset up to 60 characters.
•
Where
o
p = 2 for port 2, 3 for port 3
o
mmm = 001 - 256 for preset
o
abcdef… = hex string to be stored
o
abcdef - ?, queries current label
Note: When controlling Inline products that also use brackets
as delimiters, replace open bracket [with ‘ and closed bracket]
with " in the abcde… portion of the command. When this
command is sent out the command port the ‘ " will
automatically be replaced with [ ].
[PCCpIii]
Forces command string loaded to a specific input to be sent.
•
Where
o
p = 2 for port 2, 3 for port 3
o
ii = 01 – 16 for input
[PCCpOoo]
Forces command string loaded to a specific output to be sent.
•
Where
o
p = 2 for port 2, 3 for port 3
o
oo = 01 – 16 for output
[PCCpPmmm]
Forces command string loaded to a specific preset to be sent.
•
Where
o
p = 2 for port 2, 3 for port 3
o
mmm = 001 – 256 for preset
[PCPDpxx]
Sets projector code delay to a defined period.
•
Where
o
p = 2 for port 2, 3 for port 3
o
x = 0 for a 0 second delay
o
x = 1 for a 1 msec. delay
o
x = 2 for a 5 msec. delay
o
x = 3 for a 10 msec. delay
o
x = 4 for a 20 msec. delay
o
x = 5 for a 50 msec. delay
o
x = 6 for a 100 msec. delay, x = ? to query
[PRST]
Resets all projector command codes to null.
Preset Commands
The MSX1616 has the ability to store and recall common configurations. Both units offer 256
presets available via serial control. The MSX3216 has 48 presets available via the front panel,
while the MSX1616 has 32 presets available via the front panel.
COMMAND
DESCRIPTION
[PSVxxx]
Save current configuration to preset memory.
•
Where
o
xxx = 001 – 256
[PRCxxx]
Recall stores configuration from preset memory.
•
Where
o
xxx = 001 – 256