CE COMPLIANCE
All products exported to Europe by Inline, Inc. after January 1, 1997 have been
tested and found to comply with EU Council Directive 89/336/EEC.  These
devices conform to the following standards:

EN50081-1 (1991),  EN55022 (1987)
EN50082-1 (1992 and 1994), EN60950-92

Shielded interconnect cables must be employed with this equipment to
ensure compliance with the pertinent Electromagnetic Interference (EMI)
and Electromagnetic Compatibility (EMC) standards governing this device.

FCC COMPLIANCE
This device has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC rules.  These limits are designed to
provide against harmful interference when equipment is operated in a
commercial environment.  This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications.  Operation of
equipment in a residential area is likely to cause harmful interference, in which
case the user will be required to correct the interference at their own expense.

Summary of Contents for IN3504

Page 1: ...Operation Manual IN3504 4 In 1 Out RGBS Switcher IN3506 6 In 1 Out RGBS Switcher...

Page 2: ...de s curit Pour les mod les sans interrupteur de courant La prise de courant d alimentation sera install pr s de l quipement et sera accessible Pour les mod les avec un s lecteur d alimentation 110V...

Page 3: ...urch den gleichen oder entsprechenden Typ wie vom Hersteller empfohlen Entsorgung verbrauchter Batterien nur nach den Anweisungen des Herstellers Instalacion E Instrucciones de Seguridad Modelos Sin I...

Page 4: ...verning this device FCC COMPLIANCE This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provid...

Page 5: ...Power Switch for easy operation in rack mounted installations COMPATIBILITY The IN3500 Series switchers are passive devices which will switch a wide variety of signals While the units were primarily...

Page 6: ...and is a push push again type switch which toggles between OFF and ON each time the button is pressed The red power LED will light to indicate that the POWER switch has been activated and that an AC p...

Page 7: ...ON BLUE CONTROL 1 2 3 4 5 6 R G B S MODEL IN3506 REMOTE CONTROL 220 VOLT 120 VOLT 220 VOLT 120 VOLT AC POWER INPUT OUTPUT RED GREEN BLUE SYNC GAIN HORIZONTAL POSITION BLUE CONTROL RED GREEN BLUE SYNC...

Page 8: ...ng Example To switch to Input Channel 4 apply a contact closure between Pin 4 and Pin 7 If two channels are selected simultaneously the output of the switcher is blanked no output is selected In order...

Page 9: ...tchers contain two internal fuses If power is applied to the unit and the front panel power LED will not light after the POWER switch has been activated these fuses may be blown Open the case as descr...

Page 10: ...crambled image Solution 1 The display device connected to the output of the switcher may not be compatible with the computer output The highest resolution workstations may put out frequencies at 85 KH...

Page 11: ...ed including without limitation any implied warranty or merchantibility or fitness for any particular purpose all of which are expressly disclaimed The information in this manual has been carefully ch...

Reviews: