PROGRAMMING
When the pump is powered, the switch is at the ON position (the display shows the message:
on
) and the signal is active
on the SIGNAL cable, the pump doses according to the cycle set with the keyboard. The dosing cycle consists of 4 phases:
1. Filter time (5 seconds) fixed.The display shows the message: a mobile
“
-
“
4 digits long
2. Programmable delay time (0-999 seconds) The display shows the message:
del
3. Programmable dosing time (0-999 seconds) The display shows the message:
run
.
4. Programmable lock-out time (0-999 minutes) The display shows the countdown, which starts from the programmed
time and goes to zero. The pump does not dose during the lock-out time, even if it receives another signal on the
SIGNAL cable.
3.1 PASSWORD
The programming menu is accessed from Stand-by by pushing and holding the PROG key for at least 4 seconds; the first
item to appear is
P
(password) – by entering the correct password it is possible to enter and make changes in the menu.
To change the password scroll the menu up to item o and enter the desired password; this item may vary from 000 to 999
and save changes upon exiting the menu.
3.2 PROGRAMMING THE DELAY, DOSING AND LOCK-OUT TIMES
3.2.1
Programming the delay time
•
Place the switch in the OFF position (standby). The display shows the message:
Sby
.
•
Press the PROG key for more than 4 seconds until the display shows the message:
1 005
.
•
Press the PROG key. The red display’s first digit begins to blink.
•
Press the UP key until the blinking digit displays the desired value.
•
Press the PROG key. The next digit blinks.
•
Press the UP key until the blinking digit displays the desired value.
•
Press the PROG key. The next digit blinks.
•
Press the UP key until the blinking digit displays the desired value.
•
Press the PROG key. All of the display’s digits stop blinking.
3.2.2
Programming the dosing time
•
Place the switch in the OFF position (standby). The display shows the message:
Sby
.
•
Press the PROG key for more than 4 seconds until the green display shows the message:
1.
•
Press the UP key until the green display shows the message:
2.
•
Press the PROG key. The red display’s first digit begins to blink.
•
Press the UP key until the blinking digit displays the desired value.
•
Press the PROG key. The next digit blinks.
•
Press the UP key until the blinking digit displays the desired value.
•
Press the PROG key. The next digit blinks.
•
Press the UP key until the blinking digit displays the desired value.
•
Press the PROG key. All of the display’s digits stop blinking.
3.2.3
Programming the lock-out time
•
Place the switch in the OFF position (standby). The display shows the message:
Sby
.
•
Press the PROG key for more than 4 seconds until the green display shows the message:
1.
•
Press the UP key until the green display shows the message:
3.
•
Press the PROG key. The red display’s first digit begins to blink.
•
Press the UP key until the blinking digit displays the desired value.
•
Press the PROG key. The next digit blinks.
•
Press the UP key until the blinking digit displays the desired value.
•
Press the PROG key. The next digit blinks.
•
Press the UP key until the blinking digit displays the desired value.
•
Press the PROG key. All of the display’s digits stop blinking.
+
+
+
+
+
+
+
+
+
+
+