InHand InSwitch ISE-P Series Quick Installation Manual Download Page 3

 

 

Power Connection Diagram 

AC/DC  input  cable  connection  diagram  for  3  or  5 

Ports Model 

 

AC/DC input cable connection diagram for 8 Ports 

Model

 

 

[NOTE]: 

Before connecting the device to the AC/DC power inputs, make sure the AC/DC power source voltage is 

stable. 

L/

+

 

end is connected to the positive AC/DC wire.

 

N/

-

 

end is connected to the negative AC/DC wire.   

 

DIP Switch Setting 

The switch allows users to enable or disable the Quality of Service (QoS) function, and broadcast storm 

protection (BSP) with DIP switch on the outer panel.

 

Settings for the Fast Ethernet switches: 

DIP Switch 

Setting 

Description 

Quality 

of 

Service(QoS) 

ON 

Enable the quality of Service to handle packet priorities in two WRR queues. 
QoS and priority mapping matrix in each queue. 

Qos 3bit priority 

7.6.5.4 

3.2.1.0 

Queues 

WRR 

16 

 

OFF 

Disables the Quality of Service 

Broadcast 
Storm 
Protection 

ON 

Enables  broadcast  storm  protection  (only  allow  maximum  of  200  broadcast 
packets per second) for each Ethernet port. 

OFF 

Disable the broadcast storm protection. 

Settings for the Gigabit Ethernet switches: 

DIP Switch 

Setting 

Description 

Quality 

of 

Service(QoS) 

ON 

Enable the quality of Service to handle packet priorities in four WRR queues. 
QoS and ToS/DSCP priority mapping matrix in each queue. 

CoS Priority 

7,6 

5,4 

3,2 

1,0 

ToS/DSCP Priority 

63 to 48 

47 to 32 

31 to 16 

15 to 0 

Queues 

WRR 

 

OFF 

Disables the Quality of Service 

Broadcast 
Storm 
Protection 

ON 

Enables broadcast storm protection (at a maximum of 2000 broadcast packets 
per second) for each Ethernet port. 

OFF 

Disable the broadcast storm protection. 

 