background image

INGICS

 ​

TECHNOLOGY

 

 

-

DC Power system 

without low state while powered off

 

For some DC Power systems which can’t maintain a low state while powered off, it needs to add 

external pull Low resistance. ​

*Suggested range of this resistance is 100K~300K ohm. 

 

 

 

min 

max 

Vin (Lo) 

0V 

0.5V 

Vin (Hi) 

2V 

50V 

Accepted Power Range 

 

 

 

 

         

 INGICS TECHNOLOGY CO., LTD.    •   [email protected]    • 

WWW.INGICS.COM 