AAY2000IKI06
26
Installation manual
Ingeteam Power Technology, S.A.
1.
Connection of the communications cable supplied with the equipment, to the quick connector located on
the Ingecon
®
µWind. The Ingecon
®
μWind Interface communication kit (AAY0089) should be requested together
with the Ingecon
®
µWind.
connector for the
Ingecon
®
µWind
↔
Ingecon
®
μWind Interface
communications quick connector
Ingecon
®
μ
Wind TL
Ingecon
®
μ
Wind with transformer
2.
Once the push-pull connector has been inserted, screw down the hood to guarantee the IP65 insulating
rating.
Once the assembly has been completed, it will be possible to establish communications with the Ingecon
®
μWind
Interface through the quick connector located in the Ingecon
®
µWind.
5.3.5. Analog inputs
The equipment has two general purpose analog inputs located in the ANA.IN connector. These inputs can be used to
connect a number of devices, such as an anemometer or thermometer.
ANA.IN JP3
JP2
By default, both inputs are configured as analog inputs for a current of 0-20 mA. Should this need to be changed to
voltage inputs of 0-10 V, simply disconnect bridges JP2 (analog input 1) and JP3 (analog input 2).