TK 56171-2-OP-EN
53
The display briefly shows PROGRAMMING ZONE ON/OFF - PLEASE WAIT.
The display then confirms the new Zone 2 setting for several seconds (
).
Figure 42.
New Zone 2 Setting
The display returns to the Standard Display showing Zone 2 is off. The
setpoint for Zone 2 has been replaced with OFF as shown (
to indicate that the zone is now off.
Figure 43.
Zone Off
Starting the Diesel Engine
Diesel engine preheats and starts are automatic in both Continuous Mode
and Cycle Sentry Mode. The engine will preheat and start as required when
the unit is turned on. The engine preheat and start will be delayed in Cycle
Sentry mode if there is no current need for the engine to run. If any keys are
being pressed on the HMI Control Panel, the engine will not preheat and
start until 10 seconds after the last key is pressed.
N
No
otte
e:: If the unit is equipped with optional Electric Standby there may be
some additional prompts before the engine will start. Refer to
“Starting the Electric Motor ”for details.