18-GF74D1-1K-EN
35
Table 20.
Horizontal Right (continued)
11. Reinstall the drain pan support bracket. The bracket should be
located between the two drain plugs as shown.
Note:
For the TEM6A0C48 and TEM6A0C60 models only, to avoid
tearing the interior insulation, the drain pan support bracket
should be installed after the coil has been put into the unit in
Step 12.
Figure 36.
All other models
12. Slide the coil assembly back into the air handler cabinet.
Important:
Make sure that the coil corner locks in place under
the tab in the side left bracket to support the coil
weight in the horizontal right position.
13. For the TEM6A0C48 and TEMA0C60 only, install the drain pan
support bracket on the top of the drain pan opposite the drain
ports and as close to the end as possible
Figure 37.
TEM6A0C48 and TEM6A0C60 Only