22
S9V2-SF-2A-EN
Table 5. S9V2B060D3PSBC Cooling Airflow (continued)
S9V2B060D3PSBC Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter
Cooling
Unit Outdoor
Airflow
Setting
(CFM/ton)
External Static Pressure
0.1
0.3
0.5
0.7
0.9
Cooling
2.5 Ton
Cooling 450
CFM/Ton
CFM
1120
1117
1111
1102
1089
Watts
162
218
275
332
390
Cooling 420
CFM/Ton
CFM
1037
1035
1029
1020
1008
Watts
132
185
238
291
346
Cooling 400
CFM/Ton
CFM
997
996
991
982
970
Watts
120
171
222
274
327
Cooling 370
CFM/Ton
CFM
923
923
918
910
898
Watts
99
146
194
243
293
Cooling 350
CFM/Ton
CFM
873
873
869
861
850
Watts
86
132
177
224
273
Cooling 330
CFM/Ton
CFM
823
824
820
813
802
Watts
75
118
162
207
253
Cooling 310
CFM/Ton
CFM
773
774
771
764
754
Watts
65
106
147
191
235
Cooling 290
CFM/Ton
CFM
722
724
721
715
705
Watts
56
94
134
175
218
Cooling
3.0 Ton
(a)
Cooling 450
CFM/Ton
CFM
1336
1332
1324
1313
1299
Watts
263
329
395
462
529
Cooling 420
CFM/Ton
CFM
1250
1247
1239
1229
1216
Watts
218
280
343
406
470
Cooling 400
CFM/Ton
CFM
1193
1189
1183
1173
1159
Watts
191
251
311
372
433
Cooling 370
CFM/Ton
CFM
1105
1103
1097
1087
1075
Watts
156
212
268
325
382
Cooling 350
CFM/Ton
CFM
1046
1045
1039
1030
1018
Watts
135
189
242
296
351
Cooling 330
CFM/Ton
CFM
987
986
981
973
961
Watts
117
167
218
270
322
Cooling 310
CFM/Ton
CFM
928
927
923
915
903
Watts
100
148
196
245
295
Cooling 290
CFM/Ton
CFM
868
868
864
857
845
Watts
85
130
176
223
271
(a)
Factory Setting
Table 6. S9V2B060U4PSBC Heating Airflow
S9V2B060U4PSBC Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter
1st Stage Capacity = 37,830
2nd Stage Capacity = 58,200
Heating
Airflow
Setting
Target
Airflow
External Static Pressure
0.1
0.3
0.5
0.7
0.9
Heating 1st
Stage
Low
782
CFM
776
769
762
756
749
Temp. Rise
45
45
45
45
46
Watts
70
109
149
188
227
Medium Low
861
CFM
842
823
805
786
768
Temp. Rise
42
43
43
44
44
Watts
88
126
164
202
240
Medium
(a)
916
CFM
863
860
858
855
853
Temp. Rise
41
41
41
41
41
Watts
105
143
181
219
257
High
1027
CFM
1105
1084
1063
1042
1021
Temp. Rise
32
32
33
34
34
Watts
135
173
210
248
285
Heating 2nd
Stage
Low
990
CFM
1002
996
990
984
979
Temp. Rise
55
55
55
55
55
Watts
126
172
219
266
313
Medium Low
1090
CFM
1130
1117
1105
1092
1079
Temp. Rise
49
49
49
50
50
Watts
160
206
253
300
347
Medium
1160
CFM
1139
1133
1128
1122
1116
Temp. Rise
48
48
49
49
49
Watts
181
231
281
331
381
High
1300
CFM
1319
1307
1295
1283
1272
Temp. Rise
41
42
42
42
43
Watts
246
300
353
407
461
(a)
Factory Setting.