80206667_ed7
EN-1
EN
Product Safety Information
Intended Use:
These tools are designed to remove and install threaded fasteners.
For additional information refer to Product Safety Information Manual Form 04584983.
Manuals can be downloaded from ingersollrandproducts.com
Product Specifications
Model(s) Style
Drive
Free
Speed
Sound Level dB(A)
(ISO15744)
Vibration m/s²
(ISO28927)
Type
Size
rpm
† Pressure (L
p
) ‡ Power (L
w
)
Level
*K
Q60P3
Pistol
Square
1/4
4000
72.4
---
<2.5
---
Q60PQ1 Pistol Insert Bit 3/8
4000
72.4
---
<2.5
---
Q70P3
Pistol
Square
3/8
7000
79.3
---
3.5
1.2
Q70PQ1 Pistol Insert Bit 1/4
7000
79.3
---
3.5
1.2
Q80P3
Pistol
Square
3/8
7000
80.8
91.8
3.7
1.0
Q80PQ1 Pistol Insert Bit 1/4
7000
80.8
91.8
3.7
1.0
Q90P3
Pistol
Square
3/8
6500
78.3
---
4.6
0.9
Q110P4 Pistol
Square
1/2
5500
84.4
95.4
5.4
0.9
Q120P4 Pistol
Square
1/2
6600
81.0
92.0
4.6
0.9
Q140P4 Pistol
Square
1/2
5400
85.0
96.0
6.7
1.1
† K
pA
= 3dB measurement uncertainty
‡ K
wA
= 3dB measurement uncertainty
*K= Vibration measurement uncertainty
WARNING
Sound and vibration values were measured in compliance with internationally recognized
test standards. The exposure to the user in a specific tool application may vary from these
results. Therefore, on site measurements should be used to determine the hazard level in
that specific application.
Installation and Lubrication
Size air supply line to ensure tool’s maximum operating pressure (PMAX) at tool inlet. Drain
condensate from valve(s) at low point(s) of piping, air filter and compressor tank daily. Install
a properly sized Safety Air Fuse upstream of hose and use an anti-whip device across any
hose coupling without internal shut-off, to prevent hose whipping if a hose fails or coupling
disconnects. See drawing 16585747 and table on page 2. Maintenance frequency is shown in a
circular arrow and defined as h=hours, d=days, and m=months of actual use. Items identified as:
1. Air filter
6. Thread size
2. Regulator
7. Coupling
3. Lubricator
8. Safety Air Fuse
4. Emergency shut-off valve
9. Oil
5. Hose diameter
After each 20,000 cycles
, or as experience indicates, drain and refill the Impulse Unit Drive
Assembly using the Fluid Replacement Kit (Part No. EQ106S-K400). Lubricate the hex drive and
the output shaft before assembly.