Ingersoll-Rand PM10X-X-X-A02 Operator'S Manual Download Page 8

PM10X-XXX-XXX-A02 (en)

Page 8 of 8

TROUBLE SHOOTING

Product discharged from exhaust outlet.

S

Check for diaphragm rupture.

S

Check tightness of (14) diaphragm screw.

Air bubbles in product discharge.

S

Check connections of suction plumbing.

S

Check “O” rings between intake manifold and inlet side fluid caps.

S

Check tightness of (14) diaphragm screw.

Motor blows air or stalls.

S

Check (176) check valve for damage or wear.

S

Check for restrictions in valve / exhaust.

Low output volume, erratic flow, or no flow.

S

Check air supply.

S

Check for plugged outlet hose.

S

Check for kinked (restrictive) outlet material hose.

S

Check for kinked (restrictive) or collapsed inlet material hose.

S

Check for pump cavitation -- suction pipe should be sized at least as
large as the inlet thread diameter of the pump for proper flow if high
viscosity fluids are being pumped. Suction hose must be a non-col-
lapsing type, capable of pulling a high vacuum.

S

Check all joints on the inlet manifolds and suction connections.
These must be air tight.

S

Inspect the pump for solid objects lodged in the diaphragm chamber
or the seat area.

DIMENSIONAL DATA

(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

Figure 4

Air Inlet 1/4 - 18 N.P.T.

Inlet

Outlet

Exhaust Port 3/4 - 14 N.P.T.

K

C

P

M

D

N

B

G

H

J

L

F

E

1-1/2” Tri-Clamp

A - 11-13/16” (299.8 mm)

F - see below

L - 2-3/8” (60.3 mm)

B - 11-9/16” (293.7 mm)

G - 12-9/16” (318.9 mm)

M - 6-15/32” (164.3 mm)

C - 4” (101.6 mm)

H - 6-1/4” (158.8 mm)

N - 9/32” (7.0 mm)

D - 1-1/4” (31.8 mm)

J - 7-5/16” (185.7 mm)

P - 5-29/32” (149.9 mm)

E - see below

K - 13/32” (10.3 mm)

DIMENSIONS

“E”

“F”

PM10A-CSS-XXX-A02

13-27/32” (351.4 mm)

8-3/16” (207.9 mm)

PM10R-CSS-XXX-A02

10-25/32” (273.2 mm)

8-5/16” (211.1 mm)

PM10S-CSS-XXX-A02

13-27/32” (351.4 mm)

8-3/16” (207.9 mm)

A

E

PN 97999-1077

Summary of Contents for PM10X-X-X-A02

Page 1: ...ximum Flow Rate flooded inlet 52 2 g p m 197 6 l p m Displacement Cycle 100 p s i g 0 232 gal 0 88 lit Maximum Particle Size 1 8 dia 3 3 mm Maximum Temperature Limits diaphragm ball seal material E P...

Page 2: ...ng outlet hose or piping from pump WARNING HAZARDOUSMATERIALS Cancauseseriousin juryorpropertydamage Donotattempttoreturnapumptothe factory or service center that contains hazardous material Safe hand...

Page 3: ...inlet pressure must not exceed 10 p s i g 0 69 bar OPERATING INSTRUCTIONS S Always flush the pump with a solvent compatible with the material beingpumpedifthematerialbeingpumpedissubjectto settingup...

Page 4: ...Gasket items 19 and 33 are not required with seat options AXX CENTER SECTION OPTIONS PM10X CSS XXX A02 Aluminum Polypropylene Stainless Steel PM10A X X A02 PM10R X X A02 PM10S X X A02 Item Descriptio...

Page 5: ...to all O rings U Cups mating parts x Apply LoctiteR 242R to threads at assembly Apply Loctite 271t to threads at assembly U Apply anti seize compound to threads and bolt and flange heads which contact...

Page 6: ...Service is divided into two parts 1 Pilot Valve 2 Major Valve GENERAL REASSEMBLY NOTES S Air Motor Section Service is continued from Fluid Section repair S Inspect and replace old parts with new part...

Page 7: ...VE A replacement Major Valve Service Assembly is available separately which includes the following 637395 1formodelsPM10R X 105 4 107 2 111 132 135 136 137 138 139 140 141 166 176 2 200 233 and 236 4...

Page 8: ...meter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non col lapsing type capable of pulling a high vacuum S Check all joints on the inlet manifolds and s...