Ingersoll-Rand PE30X-XXX-XXX-C Operator'S Manual Download Page 8

Page 8 of 8 

PD30X-XXX-XXX-C (en)

PN 97999-1110

C

B

D

K

A

N

Outlet

Inlet

Exhaust Port 1-1/2 - 11-1/2 N.P.T.

Air Inlet Ports
3/4 - 14 N.P.T.F. - 1

3 - 8 N.P.T.F. - 1 

(PX30X-AXX-XXX-C)

Rp 3 (3 - 11 BSP parallel) 

(PX30X-BXX-XXX-C)

F

E

L

H

J

M

G

D

B

Q (

Bolt circle)

3” A.N.S.I / DIN Flange
(PX30X-FXX-XXX-C)

L

Q

P

TROUBLE SHOOTING

Product discharged from exhaust outlet.

Check for diaphragm rupture.
Check tightness of (14) cap screw.

Air bubbles in product discharge.

Check connections of suction plumbing.
Check “O” rings between intake manifold and fl uid caps.
Check tightness of (14) cap screw.

Motor blows air or stalls.

Check (176) check valve for damage or wear.
Check for restrictions in valve / exhaust.

y

y

y

y

y

y

y

Low output volume, erratic fl ow or no fl ow.

Check air supply.
Check for plugged outlet hose.
Check for kinked (restrictive) outlet material hose.
Check for kinked (restrictive) or collapsed inlet material hose.
Check for pump cavitation - suction pipe should be sized at 
least as large as the inlet thread diameter of the pump for 
proper fl ow if high viscosity fl uids are being pumped. Suction 
hose must be a non-collapsing type, capable of pulling a high 
volume.
Check all joints on the inlet manifolds and suction connections. 
These must be air tight.
Inspect the pump for solid objects lodged in the diaphragm 
chamber or the seat area.

y

y

y

y

y

y

y

DIMENSIONAL DATA

Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

Figure 4

DIMENSIONS

A - see below
B  -  30” (762.0 mm)
C  -  12-1/16” (306.4 mm)
D - see below
E  -  17-11/16” (449.2 mm)

F  -  15” (381.0 mm)
G - see below
H  -  10-5/32” (258.0 mm)
J - see below

K  -  9/16” (14.3 mm)
L - see below
M -  23-3/32” (586.3 mm)
N - see below

 

“A” 

“D” 

“J”                             “N”

PX30X-XAX-XXX-C 

23-5/8” (600.1 mm)     2-3/8” (60.3 mm)     11” (279.4 mm)                15-1/2” (393.7 mm)

PX30X-XCX-XXX-C 

23-5/8” (600.1 mm)     2-7/16” (61.9 mm)   11-11/16” (296.9 mm)   15-1/2” (393.7 mm)

PX30X-XHX-XXX-C 

23-1/8” (587.4 mm)     2-3/4” (69.9 mm)      11-11/16” (296.9 mm)   16” (406.4 mm)

PX30X-XSX-XXX-C 

23-1/8” (587.4 mm)     2-3/4” (69.9 mm)      11-11/16” (296.9 mm)   16” (406.4 mm)

PX30X-FXX-XXX-C 

23-1/8” (587.4 mm)     2-3/4” (69.9 mm)      11-11/16” (296.9 mm)   16” (406.4 mm)

D o t t e d   l i n e s   s h o w 
optional 67263 muffler 
assembly.

        “L”
2-3/4” (69.9 mm)
2-3/4” (69.9 mm)
2-3/4” (69.9 mm)
2-3/4” (69.9 mm)
3-3/4” (95.25 mm)

P  -  1” (25.4 mm)
Q  -  6” (152.4 mm)

        “G”
32” (812.8 mm)
32” (812.8 mm)
32” (812.8 mm)
32” (812.8 mm)
33-3/4” (857.3 mm)

Summary of Contents for PE30X-XXX-XXX-C

Page 1: ...um Particle Size 3 8 dia 9 5 mm MaximumTemperature Limits diaphragm ball seal material E P R EPDM 60 to 280 F 51 to 138 C Hytrel 20 to 150 F 29 to 66 C Kynar PVDF 10 to 200 F 12 to 93 C Nitrile 10 to...

Page 2: ...y OPERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE Obtain Material Safety Data Sheets on all materials from the supplier for proper handl...

Page 3: ...e packet is included in service kit Be certain the diaphragm assembly bottoms out on the 1 rod back off PTFE diaphragm assembly far enough to align holes For models with PTFE diaphragms Item 8 Santopr...

Page 4: ...1 1 C 94831 2 SS 94831 2 SS 68 Air Cap 1 94030 1 A 94721 1 A 94031 1 SS 94031 1 SS 69 Air Cap 1 94030 2 A 94721 2 A 94031 2 SS 94031 2 SS 76 Pipe Plug 1 8 27 N P T x 0 27 1 Y17 50 S SS Y17 50 S SS 126...

Page 5: ...anti seize compound to threads and bolt and nut flange heads which contact pump case when using stainless steel fasteners f Apply Loctite 262 to threads at assembly g Apply PTFE tape to threads h App...

Page 6: ...to 135 valve housing securing with 240 screws Assemble 132 and 166 gaskets and 176 checks to 101 cen ter body Assemble 135 valve housing and components to 101 center body securing with 134 screws 3 4...

Page 7: ...05 4 111 128 2 132 133 3 134 4 135 136 137 138 139 140 141 146 147 176 2 199 200 233 240 2 241 242 243 and 244 ASSEMBLY TORQUE REQUIREMENTS NOTE DO NOT OVERTIGHTEN FASTENERS ALL FASTENERS ARE METRIC 1...

Page 8: ...cosity fluids are being pumped Suction hose must be a non collapsing type capable of pulling a high volume Check all joints on the inlet manifolds and suction connections These must be air tight Inspe...

Reviews: