TROUBLE SHOOTING

Product discharged from air exhaust.

Check for diaphragm rupture.
Check tightness of (6) diaphragm nut.

Air bubbles in product discharge.

Check connections of suction plumbing.
Check “O” rings between intake manifold and fl uid caps.
Check tightness of (6) diaphragm nut.

Pump blows air out main exhaust when stalled on either 
stroke.

Check “U” cups on (111) spool in major valve.
Check (141) valve plate and (140) insert for wear.
Check (169) “U” cup on (167) pilot piston.

y

y

y

y

y

y

y

y

Low output volume.

Check air supply.
Check for plugged outlet hose.
For the pump to prime itself, it must be mounted in the 
vertical position so that the balls will check by gravity.
Check for pump cavitation - suction pipe should be sized 
at least as large as the inlet thread diameter of the pump 
for proper fl ow if high viscosity fl uids are being pumped. 
Suction hose must be non-collapsible type, capable of 
pulling a high vacuum.
Check all joints on the intake manifolds and suction con-
nections. These must be air tight.
Inspect the pump for solid objects lodged in the dia-
phragm chamber or the seat area.

y

y

y

y

y

y

DIMENSIONAL DATA

Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

Figure 5

DIMENSIONS

A -  10-1/16” (254.2 mm) 

E -  6-3/4” (171.0 mm) 

J -  5-17/32" (140.2 mm) 

N -  6-5/16" (160.5 mm)

B -  10-3/32” (256.1 mm) 

F -  6-1/32” (153.1 mm) 

K -  5/16” (8.0 mm) 

P -  8-7/8” (225.3 mm)

C -  6-3/16” (157.1 mm) 

G -  10-29/32” (276.8 mm)  L -  1-15/16” (48.9 mm) 

Q -  see below

D -  2” (51.0 mm) 

H -  4-29/32” (124.2 mm) 

M -  3/8” (9.6 mm)

H

J

B

G

C

M

F

E

L

K

D

N

P

A

 

(Outlet)

 Q

Q

(Inlet)

Air Inlet 1/4 - 18 P.T.F. SAE Short

Pump Model 

“Q” Material Inlet / Outlet

PD07P-APS-PXX 

3/4 - 14 N.P.T.F. - 1

PD07P-BPS-PXX 

Rp 3/4 (3/4 - 14 BSP, parallel)

Summary of Contents for PD07P-X-X

Page 1: ...Cycle 100 p s i g 0 032 gal 0 12 lit Maximum Particle Size 3 32 dia 2 4 mm MaximumTemperature Limits diaphragm ball seat material Hytrel 20 to 150 F 29 to 66 C Polypropylene 35 to 175 F 2 to 79 C Sant...

Page 2: ...ATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE comply with local and national laws and safety code requirements Obtain Material Safety Data...

Page 3: ...include the pump in preventive maintenance program Service kits are available to service two separate dia phragm pump functions 1 AIR SECTION 2 FLUID SEC TION The Fluid Section is divided further to...

Page 4: ...5 DiaphragmWasher 2 94645 GFN 6 Diaphragm Nut 5 16 18 2 93103 7 P 15 Fluid Cap 2 95732 1 P 26 Flange Bolt 5 16 18 x 7 8 4 96176 SS 27 Bolt 5 16 18 x 1 1 4 20 93095 SS 29 Hex Flange Nut 5 16 18 20 938...

Page 5: ...O rings U cups and mating parts Apply pipe sealant to threads Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when using stainless steel fasteners PARTS LIST...

Page 6: ...and inspect inner bore of bushing for damage PILOT VALVE REASSEMBLY Clean and lubricate parts not being replaced from service kit Assemble 171 O rings to 170 bushing and assemble bushing into 101 cent...

Page 7: ...er body Remove 132 gasket 141 valve plate and 140 valve insert from 135 valve block Remove 134 bolts releasing 107 and 136 plugs and 111 spool 1 2 3 4 MAJOR VALVE REASSEMBLY Assemble new 138 and 139 U...

Page 8: ...ed at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be non collapsible type capable of pulling a high vacuum Check...

Reviews: